- Automated Liquid Handling
- Calorimetry
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color, Appearance & Physical tests
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Genomic (Nucleic acids)
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Material testing
- Metrology
- Microbiology (Clinical)
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Sample preparation
- Shakers and stirrers
- Spectrometry
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Toxicology
- Urine analysis
- Viscometry
- Water purification
- Weighing
- Viscometry
- 100 cP VISCOSITY STANDARD (appx 900ml)
HOME / APPLICATIONS & TECHNIQUES /
100 cP VISCOSITY STANDARD (appx 900ml)
Reference: AME-100 CPS
https://www.analis.com/shop/ame-100-cps-100-cp-viscosity-standard-appx-900ml-15383 https://www.analis.com/web/image/product.template/15383/image_1920?unique=b312600Silicone viscosity Standard fluids are most commonly used to verify the calibration of Brookfield lab viscometers and rheometers and are less temperature sensitive than mineral oils.
General purpose silicone fluids are the most commonly used standard for verifying the calibration of your Brookfield Viscometer/Rheometer.
Silicone Standards are Newtonian fluids, which are accurate to ±1% of viscosity value.
Silicone fluids provide excellent temperature stability and are less temperature sensitive than oil viscosity standards.
Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST).
The selection of one or two fluids will normally provide sufficient measurement points to verify the calibration of your instrument.
All fluids are supplied in ½ liter (1 pint) containers complete with a certificate of calibration.
FEATURES & BENEFITS
- Accuracy: ±1% of viscosity value
- Excellent temperature stability
- Recommended for use with Brookfield and most other rotational viscometers
- Most economical
- Special viscosity values and temperature calibrations are available upon request
Available viscosity values in general-purpose Purpose Silicone Fluids (at 25°C)
- 5 cps
- 10 cps
- 50 cps
- 100 cps
- 500 cps
- 1000 cps
- 5000 cps
- 12500 cps
- 30000 cps
- 60000 cps
- 100000 cps