- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse thermique
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Essais et caractérisation des matériaux
- Fécondation in vitro (FIV)
- Hottes de Protection
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Rhéomètres
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimètres
- Électrochimie
- Essais et caractérisation des matériaux Caractérisation des surfaces et nanocouches
- QCM-D X4 – 4 Channels
HOME / APPLICATIONS & TECHNIQUES /
QCM-D X4 – 4 Channels
Référence: BION-QCMD 400
https://www.analis.com/shop/bion-qcmd-400-qcm-d-x4-4-channels-147794 https://www.analis.com/web/image/product.template/147794/image_1920?unique=ad3a0d8The QCM-D X4 is a label-free surface analysis instrument based on a quartz crystal microbalance with dissipation monitoring (QCM-D). A quartz resonator is driven to oscillate at its resonance frequency and at one or more overtones; at each overtone, the instrument measures changes in resonance frequency and energy dissipation caused by processes at the sensor surface, such as the formation of single or multilayer films or changes in their geometric or physical properties.
Built by Advanced Wave Sensors (AWSensors) for fundamental, pre-clinical and industrial research, the X4 offers 4 measurement cells with high sensitivity and real-time, in-situ monitoring.
What does the QCM-D X4 measure?
QCM-D measures mass and structural changes at a surface in real time by tracking frequency and dissipation shifts. It works in aqueous media or organic solvents, which makes it widely used to study solid/liquid interfaces, adsorption and desorption, molecular interactions and protein changes. In lipid studies, it can distinguish different geometries and shape changes of lipid compositions at interfaces, for example homogeneous solid-supported bilayers versus adsorbed liposomes or other structures such as cubosomes.
How does it work?
The underlying acoustic wave sensing (AWS) principle monitors surface-bound interactions in real time. Sensors are available with different coatings, including gold (Au), silica (SiO₂) and titania (TiO₂), so the surface chemistry can be matched to the experiment. A modular design supports standard and high-frequency QCM-D as well as LOVE-SAW sensor measurements, and an integrated potentiostat enables simultaneous QCM-D and electrochemistry.
Key advantages
- 4 measurement cells / channels
- High sensitivity and low detection limits
- Fast acquisition speed and in-situ measurement
- Modular design for standard and high-frequency QCM-D and LOVE-SAW sensor measurements; external cells can also be placed
- Quick-lock measurement cells for user-friendly handling and robust measurements
- Ethernet instrument control and data monitoring
- Integrated potentiostat control for simultaneous QCM-D and electrochemistry applications
- Optional fluidics module with integrated software control
- Compact, lightweight design with basic data analysis package and export functions
Suitable for
- Solid/liquid interface studies
- Lipid studies
- Adsorption and desorption processes
- Characterization of molecular interactions
- Protein changes
- Fundamental research, pre-clinical research and industrial applications
Request a demonstration or quote
Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Données Techniques
Category | Specification |
Number of measurement cells and channels | 4 |
Sensor types | QCM, AWS HFF‐QCM, AWS Love‐SAW |
Measurement methods | High resolution (single and multiple overtones) |
Number of overtones | Up to 7 (fundamental + 6 overtones) |
Frequency range | 4 MHz to 160 MHz |
Maximum frequency resolution | 0.1 Hz |
Frequency accuracy | ± 0.5 Hz |
Temperature range | 15°C to 45°C |
Temperature stability | ± 0.05°C |
Mass sensitivity in air | 8 pg/cm² |
Mass sensitivity in liquid | 0.6 ng/cm² |
Dimensions | 150 x 400 x 300 mm |
Weight | <10 kg |
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse thermique
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hottes de Protection
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie