- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse thermique
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Essais et caractérisation des matériaux
- Fécondation in vitro (FIV)
- Hottes de Protection
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Rhéomètres
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimètres
- Électrochimie
- Essais et caractérisation des matériaux Tests de thermoscellage et de scellage d’emballages
- HSG-3 & 5 Gradient Heat Sealer
HOME / APPLICATIONS & TECHNIQUES /
HSG-3 & 5 Gradient Heat Sealer
Référence: HSG-3-5-Grad
https://www.analis.com/shop/hsg-3-5-grad-hsg-3-5-gradient-heat-sealer-147784 https://www.analis.com/web/image/product.template/147784/image_1920?unique=ad3a0d8The RDM HSG-3 and HSG-5 Gradient Heat Sealers are laboratory instruments for fast, accurate determination of the sealability of flexible packaging materials. They produce 3 seals (HSG-3) or **5 seals (HSG-5)**, each with individually adjustable temperature control, creating a temperature gradient across a film in a single test, so you can find a material’s optimal sealing window efficiently.
HSG-3 or HSG-5: which model?
Both models work the same way; the difference is the number of seal stations:
- HSG-3 — 3 independent seals
- HSG-5 — 5 independent seals
More stations mean more temperature points per test, so the HSG-5 maps a sealing window in finer steps. Each seal is up to 15 mm wide and 30 mm long, with individual temperature control.
What does the HSG measure?
By applying a temperature gradient across the film, the HSG determines the optimal sealing characteristics of a material, the temperature range that produces a reliable seal, in one test rather than many. This makes it ideal for seal development and quality control of flexible films, blister packs and jars.
How does it work?
Digital controllers set temperature (0–300 °C, resolution 0.1 °C), pressure (0–100 psi) and dwell time (0.01–99.9 s) for accurate, reproducible results. Seal bars can be configured single-sided (top) or double-sided (top and bottom) in accordance with ASTM F2029, with surfaces including Matched Crimp and Teflon coating. Aluminum and silicone seal jaws with finely finished surfaces ensure consistent quality, and an automatic cycle function simplifies multi-sample testing.
Key advantages
- Multiple seal stations: 3 or 5 seals, each up to 15 mm wide and 30 mm long, with individual temperature control
- Precision settings: digital controllers for temperature (0–300 °C, resolution 0.1 °C), pressure (0–100 psi) and dwell time (0.01–99.9 s) for accurate, reproducible results
- Flexible configuration: single-sided (top) or double-sided (top and bottom) seal bars, in accordance with ASTM F2029
- Various seal surfaces available, including Matched Crimp and Teflon coating
- Automatic cycle function for easier testing of multiple samples
- Robust construction: aluminum and silicone seal jaws with finely finished surfaces for consistent seal quality
Suitable for
- Flexible films
- Blister packs
- Jars
Request a demonstration or quote
Download the brochure below for full specifications. Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Données Techniques
Category | Specification |
Temperature range | 0-300 °C (resolution 0.1 °C, accuracy ±2 °C) |
Pressure control | 0-100 psi (accuracy ±5%, repeatability ±0.02 psi) |
Dwell time | 0.01-99.9 sec (accuracy ±5%) |
Seal dimensions | Up to 15 mm wide x 30 mm long |
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse thermique
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hottes de Protection
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie