- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Enceintes de Protection
- Essais et caractérisation des matériaux
- Fécondation in vitro (FIV)
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Rhéomètres
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimètres
- Électrochimie
- Purification de l'eau
- Genie R 32 System set
HOME / APPLICATIONS & TECHNIQUES /
Genie R 32 System set
Référence: REP-RG0R03000K
https://www.analis.com/shop/rep-rg0r03000k-genie-r-32-system-set-10564 https://www.analis.com/web/image/product.template/10564/image_1920?unique=03e9e49Genie R produces reverse osmosis (RO) laboratory-grade water from tap water directly. It applies high recovery reverse osmosis (RO) technology to produce pure water for general laboratory needs with easy maintenance and low running costs. Genie R offers desired solutions for research professionals who work with a variety of applications utilizing RO pure water in the lab.
The system is CE/RoHS certified. RephiLe provides full document support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via wired or wireless. “1+N” Mode.
- Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
- Fully automated control system has cleaning, rising, flush and many other functions.
- System automatically rinses a new RO membrane. User does not need to set special rinse program for a new RO membrane.
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- The Chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
- Leak protector is incorporated inside to shut the feed water off to prevent damage from leakage.
- A tank sanitization module can be used to effectively keep microbial growth at a lower level by LED UVC light.
- Tank recirculation model guarantees water quality in the tank.
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. Cartridge
Pre-filtration pack removes most large particles, chlorine, calcium or organic compounds to protect RO membrane to extend their usable life.
AC Pack contains special activated carbon to remove organic impurities and free chlorines.
2. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
The console screen and dispenser screens are water-drop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
3. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
4. Level sensor
The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
Water level and quality inside the tank can be viewed from the control console.
Données Techniques
| Feed Water Requirements | |
| Tap water | Municipal water, Conductivity < 2000 μS/cm (1000 ppm) |
| Operating temperature | 5 - 35 ℃ |
| Feed water pressure | 1 - 6 bar psi (15 - 90) |
| Water Flow Rate | |
| Water production rate (@ 25℃) | 12, 24, 32 L/hr |
| Water dispensing rate | Up to 2.0 L/min |
| Product Water Quality | |
| Water conductivity (@ 25℃) | typically < 20 μS/cm (feed water conductivity < 500 μS/cm) |
| RO rejection | 97 to 98% ionic rejection (new RO cartridge) > 99% organic rejection > 99% particulates & bacteria rejection |
| Product Water Quality Stored in Tank (for tank recirculation models) | |
| Resistivity (@25℃) | > 1 MΩ·cm (default), adjustable |
| Dimensions | |
| Main system dimensions Width × depth × height | 32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in) |
| Dispenser dimensions Width × depth × height | 21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in) |
| Weight | 20 kg |
| Input Voltage | 110 - 240 VAC |
| Operating Voltage | 24 VDC |
| Main system power | < 200 W |
*Product water quality may vary due to local feed water conditions.
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie