- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Enceintes de Protection
- Essais et caractérisation des matériaux
- Fécondation in vitro (FIV)
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Rhéomètres
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimètres
- Électrochimie
- Purification de l'eau
- Genie PURIST System set
HOME / APPLICATIONS & TECHNIQUES /
Genie PURIST System set
Référence: REP-RG0S00000K
https://www.analis.com/shop/rep-rg0s00000k-genie-purist-system-set-10568 https://www.analis.com/web/image/product.template/10568/image_1920?unique=03e9e49Genie PURIST ultrapure water system produces Type I ultrapure water from RO, distilled or deionized water and it is designed for critical laboratory applications, offering desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure water in the lab. Quality of ultrapure water meet or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via wired or wireless.
- An optional automatic system shut-off upon detection of any water leakage.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- A universal water level sensor can be provided to prevent the system from pumping air.
Effective TOC level controlment
- Built-in 185/254 nm dual wavelength lamp reduces TOC level in ultrapure water.
- On-line TOC monitor based on complete oxidation methods (for TOC models).
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. Cartridge
Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
A full range of cartridges for various applications including ultra-low TOC, low Mg, low boron, ICP and DI type.
2. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
The console screen and dispenser screens are water-frop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
3. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
4. Final Filter
Various final filters (optional) are applicable to ensure ultrapure water without particles, bacteria or pyrogen.
Données Techniques
| Feed Water Requirements | |
| Pure water | EDI water, RO water, Distilled water, Deionized water |
| Operating temperature | 5 - 35 ℃ |
| Feed water pressure | 0 - 1 bar (0 - 15 psi) |
| Product Water Quality | |
| Ultrapure water dispensing rate | Up to 2.0 L/min |
| Ultrapure water resistivity (@ 25℃) | 18.2 MΩ·cm |
| Ultrapure water TOC* | < 2 ppb |
| Particles in ultrapure water ( > 0.2 μm) | No particles (with a 0.2 μm final filter or RephiBio filter) |
| Microorganisms in ultrapure water | < 0.001 cfu/ml (with a 0.2 μm final filter or RephiBio filter) |
| Pyrogens (endotoxins) in ultrapure water | < 0.001 Eu/ml (with a RephiBio filter) |
| RNase in ultrapure water | < 0.5 pg/ml (with a RephiBio filter) |
| DNase in ultrapure water | <10 pg/ml (with a RephiBio filter) |
| Dimensions | |
| Main system dimensionsWidth × depth × height | 32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in) |
| Dispenser dimensionsWidth × depth × height | 21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in) |
| Weight | 17 kg |
| Input Voltage | 110 - 240 VAC |
| Operating Voltage | 24 VDC |
| Main system power | < 200 W |
*In the appropriate operating conditions, otherwise typically ≤5 ppb.
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie