Onze oplossingen
Experience the power and speed of SCIEX separations technology
SCIEX capillary electrophoresis instruments were developed to address your analytical challenges today, while keeping one eye focused firmly on the demands of tomorrow.
Whether your lab is performing clone selection, automated and quantitative analysis of biologics, proteomic, metabolomic or genomic research, or food and environmental testing, SCIEX is sure to have a state-of-the-art solution for you.
Meer informatie about our capillary electrophoresis instruments, and see why scientists around the world rely on SCIEX technology to bring their research into the future.
Neem contact met ons op om te bespreken welk instrument het beste past bij uw behoeften en budget.
BioPhase 8800
Innovatief systeem voor de parallelle en simultane verwerking van 8 monsters, terwijl het gevoelige CE-SDS en CIEF analyses levert. Zorgt voor compromisloze precisie en snellere responstijden tijdens het hele biologische ontwikkelproces.
Meer informatiePA 800 Plus Pharmaceutical Analysis System
Flexibel platform voor meerdere analytische assays met een capillair met temperatuurregeling voor de grootst mogelijke reproduceerbaarheid en betrouwbaarheid van data.
CESI 8000 Plus ESI-MS-High-Performance System
Integreert capillaire elektroforese en elektrospray-ionisatie (ESI) in één dynamisch proces. Verhoogt de scheidingsefficiëntie, snelheid en gevoeligheid aanzienlijk.
P/ACE™ MDQ Plus
Geautomatiseerde, programmeerbare capillaire elektroforesesystemen voor de snelle scheiding van complexe monsters.
Speciale inruilactie
Upgrade naar Next-Gen Capillaire Elektroforese. Ruil uw verouderde CE-systeem in en ontvang een speciale korting op het nieuwste model. Profiteer van verbeterde prestaties, betrouwbaarheid en ondersteuning. Neem contact op met onze experts om de ideale oplossing voor jouw workflow samen te stellen.
Vraag info over inruilvoorwaardenOnze producten
eCAP™ Neutral Coated Capillary with laser burned window - 50 µm ID x 67 cm total length.
Capillary used with the Advanced cIEF Starter Kit (Part number A80976).
Capillaries must be trimmed to optimize for speed/resolution.
This capillary is also suitable for other applications where no EOF is desired. Thanks to the polyacrylamide coating, no EOF is present. The capillary can be used with both UV and LIF detection systems but capillary life is impacted when used with diodearray detection systems.
SDS-MW Gel Buffer is a 4-pack of the SDS-MW gel used in the SDS-MW Kit (Part Number 390953) and the IgG Purity and Heterogeneity Kit Assay (Part Number A10663).
SDS-MW gel designed for the separation and sizing of protein samples, utilizing SDS complexes as a replaceable gel matrix.
De SDS-Gel MW-analysekit is ontworpen voor de scheiding en kwantificering van eiwit-SDS-complexen m.b.v. een vervangbare gelmatrix. De gel is zo samengesteld dat deze een effectief eiwitzeefbereik van ongeveer 10 tot 225 kDa biedt. Binnen dit groottebereik is de logaritme van de moleculaire massa van het eiwit lineair met de reciproke elektroforetische mobiliteit. Zo kan het molecuulgewicht van een onbekend eiwit worden geschat a.d.h.v. een standaardcurve van bekende eiwitgroottes. Deze chemie kan ook worden gebruikt om de hoeveelheid eiwit effectief te kwantificeren en de zuiverheid van een eiwitproduct te bepalen.
Inhoud:
• Scheidingscapillair, 57 cm x 50 µm ID, ongecoat gesmolten silica, (2)
• SDS-gelseparatiebuffer, 140 ml
• SDS-monsterbuffer, 100 mM Tris-HCl, pH 9,0/1% SDS, 50 ml
• SDS-eiwitgroottestandaard (10 tot 225 kDa), 16 mg/ml, 100 µl
• Interne standaard, 10 kDa-eiwit, 5 mg/ml, 0,4 ml
• Zure wasoplossing, 0,1 N HCl, 100 ml
• Basische wasoplossing, 0,1 N NaOH, 100 ml
• SDS-gel MW-analysegids (1)
Loading Solution for DNA sequencing and fragment analysis samples
Contains cartridge body, 100 x 800 µm aperture, 100 x 200 µm aperture, tubing kit, nuts, ferrules, and O-rings. This cartridge body comes with 60 cm coolant tubing installed and also includes 30, 40, and 50 cm tubing.
Separation Buffer for performing capillary Isoelectric Focusing.
(100 mL).
Gel used in the cIEF application for experimentally determining a molecule's isoelectric point (pI) and the various charge variants of the molecule.
pI Marker Kit features synthetic peptides for high resolution and quantitative reproducibility in calculating protein pI. The combination of the advanced cIEF methods, the synthetic pI markers, and the PA 800 Plus system results in cIEF separations with the highest level of precision for pI determination and isoform quantitation of your sample.
This kit includes:
• Five vials containing 240 µL each of peptides with the following pI values: pI 4.1, pI 5.5, pI 7.0, pI 9.5, pI 10.0.
This volume enables 100 cIEF runs.
De eCAP dsDNA 1000 Kit is ontworpen voor DNA-fragmentpatroonherkenning, kwantificering van PCR-fragmenten en moleculaire groottebepaling op SCIEX CE-systemen. Deze chemie maakt gebruik van lineair polyacrylamide in oplossing om een zeefgel te vormen. Een neutrale capillair die bij deze kit wordt geleverd, heeft een stabiele, fysiek gebonden polyacrylamidecoating die elektro-osmotische stroming (EOF) elimineert en interacties van het monster met de capillaire wand onderdrukt. Dit chemische proces maakt gebruik van een standaard Tris-Boraat EDTA-buffer, waarbij intercalerende kleurstoffen zoals ethidiumbromide of ons eigen EnhanCE™ kunnen worden toegevoegd om de resolutie te verbeteren en de gevoeligheid te verhogen. Deze kit is ideaal voor de analyse van dubbelstrengs DNA-fragmenten van 72 tot 1000 basenparen en voor de analyse van PCR-producten, die direct kunnen worden geanalyseerd zonder reiniging van het monster. Toepassingen van deze kit zijn onder meer genexpressieanalyse (competitieve PCR) en genotyperingsexperimenten. Het systeem is compatibel met zowel uv- als LIF-detectie, maar voor de meeste toepassingen wordt LIF aanbevolen. Voor LIF-toepassingen raden we het gebruik van de intercalerende kleurstof EnhanCE aan. Deze kit is niet compatibel met PDA-detectie.
De kit bevat reagentia voor de analyse van 100 monsters en bestaat uit:
> 100 µm I.D. 65 cm, 2 neutrale capillairen (DNA),
> flesjes met vervangbare polyacrylamidegel,
> testmix bestaande uit HaeIII-restrictie-digest 174 DNA met 11 fragmenten van 72 bp tot 1353 bp,
> en instructies en methoden voor het instellen en analyseren van het systeem.




