- Analytische chemie
- Beschermingskasten
- Biologische beeldvorming
- Bloedplaatjesaggregatie
- Capillaire elektroforese
- Celculturen en fermentatie
- Cellulaire analyse
- Centrifugatie
- Chromatografie (flash & prep)
- DNA / RNA (nucleïnezuren)
- Deeltjeskarakterisatie
- Desinfectie
- Elektrochemie
- Flowcytometrie
- Flowcytometrie celsorting
- Geautomatiseerde Liquid Handling
- Hematologie
- Immuno-hematologie
- Immunodosage
- In-vitrofertilisatie (IVF)
- Kleur-Appearance en fysische testen
- Klinische IT-oplossingen
- Klinische automatisering (TLA)
- Klinische chemie
- Klinische kwaliteitscontroles
- Laboratoriummeubilair & ontwerpstudies
- Massaspectrometers
- Mechanische testen
- Metrologie
- Microbiologie (Klinische)
- Microscopie
- Monstersvoorbereiding
- Nefelometrie
- Omgevingscontrole
- Opslag
- POCT
- Pipetteren van vloeistoffen (handmatig)
- Pompen
- Reinigen
- Shakers and stirrers
- Sterilisatie
- Synthese
- Tablet testing
- Texturometers
- Toxicologie
- Urineanalyse
- Verwarmen & koelen
- Viscometrie
- Vochtanalyse
- Vriesdrogen
- Waterzuivering
- Wegen
- Beschermingskasten Cytotoxische kasten
- CYT-4A1 Cytoculture® Cytotoxic Safety Cabinet, 1.2m
HOME / APPLICATIONS & TECHNIQUES /
CYT-4A1 Cytoculture® Cytotoxic Safety Cabinet, 1.2m
Referentie: ESC-2060004
https://www.analis.com/shop/esc-2060004-cyt-4a1-cytoculture-r-cytotoxic-safety-cabinet-1-2m-14172 https://www.analis.com/web/image/product.template/14172/image_1920?unique=689d05dEsco’s Cytoculture® Cytotoxic Safety Cabinet is the premium solution for cytotoxic/antineoplastic drug processing; providing the highest level of patient, pharmacist, and environmental protection. This revolutionary product builds on Esco’s experience of more than 20 years as a global leader in biological safety containment technology.
The unique demands of handling and preparing cytotoxic drugs for use in chemotherapy require a specialized cabinet. With this in mind, Esco has developed a highly specialized cabinet designed especially for the preparation of these potentially dangerous drugs.
Key Benefits:
Safe filter changing
Safer dual exhaust filters
HEPA certified to EN 12469
Technische Informatie
| Section | Specifications |
|---|---|
| A. General Construction | |
| External Dimensions (W x D x H) | 1420 x 846 x 2190 mm (55.9” x 33.3” x 86.2”) |
| Internal Work Area (W x D x H) | 1270 x 620 x 670 mm (50.0” x 24.4” x 26.4”) |
| Tested Opening | 203 mm (8.0”) |
| Material | Main Body: 1.5 mm (0.06”) 16-gauge electrogalvanized steel with white oven-baked epoxy-polyester ISOCIDE™ antimicrobial powder-coated finish Work Zone: 1.5 mm (0.06”) 16-gauge stainless steel Type 304 with No.4 finish Side Walls: 1.2 mm (0.06”) 16-gauge stainless steel Type 304 with No.4 finish |
| Weight | 383 Kg (844 lbs) |
| B. Blower and Filtration | |
| Blower | Direct drive, permanently lubricated centrifugal blower/motor, dynamically balanced in two planes compliant with ISO 2710 for low noise, low vibration, and long filter life. |
| Filtration | Tri-filter system: Supply downflow filter and two exhaust filters Downflow and exhaust ULPA filters: ULPA-type per IEST-RP-CC001.3 or H14 per EN 12469 One exhaust filter: V-Bank design HEPA-type per IEST-RP-CC001.3 or H14 per EN 12469 |
| Airflow Velocity (Inflow) | 0.45 m/s (90 fpm) |
| Air Quality | ISO 14644-1 Class 3 |
| C. Control Panel and Electrical | |
| Controller | Sentinel™ Silver Microprocessor Controller Soft touch keys for Blower, Light, and UV lamp with LED light UV timer Audible and visual alarms |
| Electrical Requirements | Power Rating: 220-240 VAC, 50 Hz, 1 phase Nominal Power Consumption: 429 W Heat Dissipation: 1464 BTU/hr |
| Lighting | Fluorescent lamp intensity: >1300 Lux (>121 foot candles) Optional UV Lamp |
| D. Ergonomics | |
| Serviceability | Easy-to-service with all electrical components located at the back of the front panel |
| Sash | Frameless, motorized sash with microprocessor-controlled movement |
| Control Panel Location | Centered and angled-down location |
| Noise Emission | Low noise level of 61 dBA |
| Arm Rest | Angled arm rest for comfortable working position |
| Work Area Corners | Easy-to-clean coved corners and smoothly finished corners |
| Knee Space | 245 mm (9.6”) for sitting position |
| E. Accessories | |
| Additional Features | Anti-Blowback Valve Carbon Filter Option (alternative to V-shaped HEPA filter) Thimble Exhaust Collar (10 inches in diameter) UV Lamp IV Bar Electrical outlet Service fixtures |
Beschermingskasten
Biologische beeldvorming
Bloedplaatjesaggregatie
Capillaire elektroforese
Celculturen en fermentatie
Cellulaire analyse
Centrifugatie
Chromatografie (flash & prep)
DNA / RNA (nucleïnezuren)
Deeltjeskarakterisatie
Desinfectie
Elektrochemie
Flowcytometrie
Flowcytometrie celsorting
Geautomatiseerde Liquid Handling
Hematologie
Immuno-hematologie
Immunodosage
In-vitrofertilisatie (IVF)
Kleur-Appearance en fysische testen
Klinische IT-oplossingen
Klinische automatisering (TLA)
Klinische chemie
Klinische kwaliteitscontroles
Laboratoriummeubilair & ontwerpstudies
Massaspectrometers
Mechanische testen
Metrologie
Microbiologie (Klinische)
Microscopie
Monstersvoorbereiding
Nefelometrie
Omgevingscontrole
Opslag
POCT
Pipetteren van vloeistoffen (handmatig)
Pompen
Reinigen
Shakers and stirrers
Sterilisatie
Synthese
Tablet testing
Texturometers
Toxicologie
Urineanalyse
Verwarmen & koelen
Viscometrie
Vochtanalyse
Vriesdrogen
Waterzuivering
Wegen