- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometry
- Water purification
- Weighing
- Protection cabinets Cytotoxic cabinets
- CYT-4A1 Cytoculture® Cytotoxic Safety Cabinet, 1.2m
HOME / APPLICATIONS & TECHNIQUES /
CYT-4A1 Cytoculture® Cytotoxic Safety Cabinet, 1.2m
Reference: ESC-2060004
https://www.analis.com/shop/esc-2060004-cyt-4a1-cytoculture-r-cytotoxic-safety-cabinet-1-2m-14172 https://www.analis.com/web/image/product.template/14172/image_1920?unique=689d05dEsco’s Cytoculture® Cytotoxic Safety Cabinet is the premium solution for cytotoxic/antineoplastic drug processing; providing the highest level of patient, pharmacist, and environmental protection. This revolutionary product builds on Esco’s experience of more than 20 years as a global leader in biological safety containment technology.
The unique demands of handling and preparing cytotoxic drugs for use in chemotherapy require a specialized cabinet. With this in mind, Esco has developed a highly specialized cabinet designed especially for the preparation of these potentially dangerous drugs.
Key Benefits:
Safe filter changing
Safer dual exhaust filters
HEPA certified to EN 12469
Technical information
| Section | Specifications |
|---|---|
| A. General Construction | |
| External Dimensions (W x D x H) | 1420 x 846 x 2190 mm (55.9” x 33.3” x 86.2”) |
| Internal Work Area (W x D x H) | 1270 x 620 x 670 mm (50.0” x 24.4” x 26.4”) |
| Tested Opening | 203 mm (8.0”) |
| Material | Main Body: 1.5 mm (0.06”) 16-gauge electrogalvanized steel with white oven-baked epoxy-polyester ISOCIDE™ antimicrobial powder-coated finish Work Zone: 1.5 mm (0.06”) 16-gauge stainless steel Type 304 with No.4 finish Side Walls: 1.2 mm (0.06”) 16-gauge stainless steel Type 304 with No.4 finish |
| Weight | 383 Kg (844 lbs) |
| B. Blower and Filtration | |
| Blower | Direct drive, permanently lubricated centrifugal blower/motor, dynamically balanced in two planes compliant with ISO 2710 for low noise, low vibration, and long filter life. |
| Filtration | Tri-filter system: Supply downflow filter and two exhaust filters Downflow and exhaust ULPA filters: ULPA-type per IEST-RP-CC001.3 or H14 per EN 12469 One exhaust filter: V-Bank design HEPA-type per IEST-RP-CC001.3 or H14 per EN 12469 |
| Airflow Velocity (Inflow) | 0.45 m/s (90 fpm) |
| Air Quality | ISO 14644-1 Class 3 |
| C. Control Panel and Electrical | |
| Controller | Sentinel™ Silver Microprocessor Controller Soft touch keys for Blower, Light, and UV lamp with LED light UV timer Audible and visual alarms |
| Electrical Requirements | Power Rating: 220-240 VAC, 50 Hz, 1 phase Nominal Power Consumption: 429 W Heat Dissipation: 1464 BTU/hr |
| Lighting | Fluorescent lamp intensity: >1300 Lux (>121 foot candles) Optional UV Lamp |
| D. Ergonomics | |
| Serviceability | Easy-to-service with all electrical components located at the back of the front panel |
| Sash | Frameless, motorized sash with microprocessor-controlled movement |
| Control Panel Location | Centered and angled-down location |
| Noise Emission | Low noise level of 61 dBA |
| Arm Rest | Angled arm rest for comfortable working position |
| Work Area Corners | Easy-to-clean coved corners and smoothly finished corners |
| Knee Space | 245 mm (9.6”) for sitting position |
| E. Accessories | |
| Additional Features | Anti-Blowback Valve Carbon Filter Option (alternative to V-shaped HEPA filter) Thimble Exhaust Collar (10 inches in diameter) UV Lamp IV Bar Electrical outlet Service fixtures |
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometry
Water purification
Weighing