- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Enceintes de Protection
- Essais de matériaux
- Fécondation in vitro (FIV)
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimétrie
- Électrochimie
- Viscosimétrie
- LVDVNext Cone/Plate rheometer with magnetic coupling and temperature probe
HOME / APPLICATIONS & TECHNIQUES /
LVDVNext Cone/Plate rheometer with magnetic coupling and temperature probe
Référence: AME-XDVNXLVDJG0G00
https://www.analis.com/shop/ame-xdvnxlvdjg0g00-lvdvnext-cone-plate-rheometer-with-magnetic-coupling-and-temperature-probe-136528 https://www.analis.com/web/image/product.template/136528/image_1920?unique=0f1fa70The DVNext Wells-Brookfield Cone/Plate Rheometer, now with an easy-to-change magnetic cone/plate, gives researchers a sophisticated instrument for routinely determining absolute viscosity of fluids in small sample volumes. Its cone and plate geometry provides the precision necessary for development of complete rheological data.
FEATURES AND BENEFITS
- Determine absolute viscosity of small samples (0.5–2.0 mL)
- Precise shear rates for determining a material's flow curve behavior
- Rapid temperature control due to small sample size
- Magnetic coupling attachment for simplified spindle attachment and removal
- Electronic gap adjustment for simplified setup and increased throughput
- Touch Screen Display available on DVNext Rheometers
- Auto-zero function to ensure precision torque measurement
- Auto-range function to define full-scale-range (FSR) for all spindle/speed combinations
- Torque measurement accuracy: 1% of full-scale range
- Repeatability: 0.2% of full-scale range
What's Included with AME-XDVNXLVDJG0G00 package of the LVDVNext Cone & Plate Rheometer with magnetic coupling and temperature probe?
- Instrument
- Lab Stand**
- Carrying Case
Note: Requires at least 1 CPA or CPM spindle and 1 CPA sample cup to operate.
**Type of stand depends on model chosen
TORQUE EXPLANATIONS
- LV is for low-viscosity materials and can measure the thinnest materials. Typical examples include inks, oils, and solvents.
- RV is for medium viscosity materials than those measured with an LV torque. Typical examples include creams, food, and paints.
- HA is for higher viscosity materials than those measured with an RV torque. Typical examples include gels, chocolate and epoxies.
- HB is for even higher viscosity materials than those measured with an HA torque spring. Typical examples include asphalt, caulking compounds, and molasses.
Having difficulties determining what instrument is best for you? Ask Analis local experts for support.
Données Techniques
Viscosity Range* cP(mPa·s)
| MODEL | Cone Spindle: CPA-40Z, CPM 40-Z | Cone Spindle: CPA-41Z, CPM-41Z | Cone Spindle: CPA-42Z, CPM-42Z | Cone Spindle: CPA-51Z, CPM-51Z | Cone Spindle: CPA-52Z, CPM-52Z | RPM | SPEEDS |
| Sample Volume: .5mL | Sample Volume: 2.0mL | Sample Volume: 1.0mL | Sample Volume: .5mL | Sample Volume: .5mL | Number of Increments | ||
| Shear Rate (sec-1): 7.5N | Shear Rate (sec-1): 2.0N | Shear Rate (sec-1): 3.84N | Shear Rate (sec-1): 3.84N | Shear Rate (sec-1): 2.0N | |||
| DVNXLVCP or DVNXLVDJG | 0.1-3K | .5-11K | .2-6K | 2-48K | 3-92K | 0.01-250 | 2.6K |
| DVNXRVCJG or DVNXRVDJG | 1-32K | 5-122K | 2-64K | 20-512K | 39-983K | 0.01-250 | 2.6K |
| DVNXHACJG or DVNXHADJG | 2.6-65K | 10-245K | 5-128K | 41-1M | 78-2M | 0.01-250 | 2.6K |
| DVNXHBCJG or DVNXHBDJG | 10.5-261K | 39-982K | 20-512K | 163-4M | 314-7.8M | 0.01-250 | 2.6K |
B=1 Billion M=1 million cP=Centipoise mPa·s=Millipascal·seconds mL=Milliliter N=RPM
e.g. Spindle CPA-40Z 7.50x10(rpm)=75.0 sec-1
*Dependant upon cone selected.
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais de matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimétrie
Électrochimie