- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometry
- Water purification
- Weighing
- Viscometry
- LVDVNext Cone/Plate rheometer with magnetic coupling and temperature probe
HOME / APPLICATIONS & TECHNIQUES /
LVDVNext Cone/Plate rheometer with magnetic coupling and temperature probe
Reference: AME-XDVNXLVDJG0G00
https://www.analis.com/shop/ame-xdvnxlvdjg0g00-lvdvnext-cone-plate-rheometer-with-magnetic-coupling-and-temperature-probe-136528 https://www.analis.com/web/image/product.template/136528/image_1920?unique=0f1fa70The DVNext Wells-Brookfield Cone/Plate Rheometer, now with an easy-to-change magnetic cone/plate, gives researchers a sophisticated instrument for routinely determining absolute viscosity of fluids in small sample volumes. Its cone and plate geometry provides the precision necessary for development of complete rheological data.
FEATURES AND BENEFITS
- Determine absolute viscosity of small samples (0.5–2.0 mL)
- Precise shear rates for determining a material's flow curve behavior
- Rapid temperature control due to small sample size
- Magnetic coupling attachment for simplified spindle attachment and removal
- Electronic gap adjustment for simplified setup and increased throughput
- Touch Screen Display available on DVNext Rheometers
- Auto-zero function to ensure precision torque measurement
- Auto-range function to define full-scale-range (FSR) for all spindle/speed combinations
- Torque measurement accuracy: 1% of full-scale range
- Repeatability: 0.2% of full-scale range
What's Included with AME-XDVNXLVDJG0G00 package of the LVDVNext Cone & Plate Rheometer with magnetic coupling and temperature probe?
- Instrument
- Lab Stand**
- Carrying Case
Note: Requires at least 1 CPA or CPM spindle and 1 CPA sample cup to operate.
**Type of stand depends on model chosen
TORQUE EXPLANATIONS
- LV is for low-viscosity materials and can measure the thinnest materials. Typical examples include inks, oils, and solvents.
- RV is for medium viscosity materials than those measured with an LV torque. Typical examples include creams, food, and paints.
- HA is for higher viscosity materials than those measured with an RV torque. Typical examples include gels, chocolate and epoxies.
- HB is for even higher viscosity materials than those measured with an HA torque spring. Typical examples include asphalt, caulking compounds, and molasses.
Having difficulties determining what instrument is best for you? Ask Analis local experts for support.
Technical information
Viscosity Range* cP(mPa·s)
| MODEL | Cone Spindle: CPA-40Z, CPM 40-Z | Cone Spindle: CPA-41Z, CPM-41Z | Cone Spindle: CPA-42Z, CPM-42Z | Cone Spindle: CPA-51Z, CPM-51Z | Cone Spindle: CPA-52Z, CPM-52Z | RPM | SPEEDS |
| Sample Volume: .5mL | Sample Volume: 2.0mL | Sample Volume: 1.0mL | Sample Volume: .5mL | Sample Volume: .5mL | Number of Increments | ||
| Shear Rate (sec-1): 7.5N | Shear Rate (sec-1): 2.0N | Shear Rate (sec-1): 3.84N | Shear Rate (sec-1): 3.84N | Shear Rate (sec-1): 2.0N | |||
| DVNXLVCP or DVNXLVDJG | 0.1-3K | .5-11K | .2-6K | 2-48K | 3-92K | 0.01-250 | 2.6K |
| DVNXRVCJG or DVNXRVDJG | 1-32K | 5-122K | 2-64K | 20-512K | 39-983K | 0.01-250 | 2.6K |
| DVNXHACJG or DVNXHADJG | 2.6-65K | 10-245K | 5-128K | 41-1M | 78-2M | 0.01-250 | 2.6K |
| DVNXHBCJG or DVNXHBDJG | 10.5-261K | 39-982K | 20-512K | 163-4M | 314-7.8M | 0.01-250 | 2.6K |
B=1 Billion M=1 million cP=Centipoise mPa·s=Millipascal·seconds mL=Milliliter N=RPM
e.g. Spindle CPA-40Z 7.50x10(rpm)=75.0 sec-1
*Dependant upon cone selected.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometry
Water purification