Se rendre au contenu
MEMMERT

ICO240 241l CO2 Incubator ICO with standard sterilisation program

Référence: MEM-ICO240

https://www.analis.com/web/image/product.template/3977/image_1920?unique=a58e321

Safety at all times: high-end functions for the protection of cell, bacteria and tissue cultures

For labs running large batches or high sample throughput, the Memmert ICO240 is the flagship of the ICO range — the largest of four available volumes (56 to 241 L) — offering 12 shelf positions and 140 kg total load capacity while retaining the full redundant safety architecture of the ICO family: dual Pt100 sensors, dual-beam NDIR CO₂ control, and AutoSAFETY thermal protection. It is the natural choice for facilities scaling up cell, bacteria or tissue culture operations without compromising on monitoring reliability.

Key technical highlights:

  • Dual-beam NDIR CO₂ control: digital electronic regulation with auto-diagnostic system, acoustic fault indication, and barometric pressure compensation
  • Twin Pt100 temperature sensors (DIN Class A, 4-wire): mutual monitoring, automatic error takeover, accuracy ±0.1 K at 37°C
  • AutoSAFETY (ASF): independent over-/undertemperature protection following setpoint at preset tolerance; automatic heating/cooling cutoff; visual and acoustic alarm
  • Built-in sterilization program: 60 minutes at 180°C, without removing the sensors
  • ControlCOCKPIT TwinDISPLAY: adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT color displays, 9 languages (DE, EN, ES, FR, PL, CZ, HU, IT, ZH)
  • SetpointWAIT function: process/program time only starts once the set temperature is reached
  • 6-side full-surface heating concept: four-side heating plus additional door and back heating to avoid condensation, even in the largest chamber of the range
  • Ethernet LAN / USB connectivity: AtmoCONTROL software for programming, management and data transfer; program retained in memory in case of power failure
  • Mobile alarm notifications: visual and acoustic alarm plus remote alert if temperature, CO₂, O₂ or humidity ranges are exceeded
  • High-capacity chamber: up to 12 internals, 140 kg total load, 15 kg per shelf
  • 3 years worldwide guarantee

    This combination does not exist.

    Données Techniques

    Specification Detail
    Interior volume 241 L
    Interior dimensions (W x H x D) 600 x 810 x 500 mm (D less 35mm for fan)
    Interior material Stainless steel 1.4301 (ASTM 304), corrosion resistant
    Exterior dimensions (W x H x D) 759 x 1180 x 691 mm (D +56mm door handle)
    Housing rear Zinc-plated steel
    Working temperature range 5°C above ambient to +50°C
    Setting temperature range +18°C to +50°C
    Setting accuracy (temperature) 0.1°C
    Temperature variation in chamber at 37°C ±0.3 K
    Temperature fluctuation over time at 37°C ±0.1 K
    Temperature sensors 2x Pt100, DIN Class A, 4-wire circuit
    CO₂ adjustment range 0–20%
    CO₂ setting accuracy 0.1%
    CO₂ variation over time ±0.2%
    CO₂ control technology Dual-beam NDIR, digital electronic
    O₂ adjustment range 1–20%
    O₂ setting accuracy 0.1%
    Humidity (standard, Peltier-limited) 93% rh ±2.5% (with water dish full and inserted)
    Humidity setting accuracy 0.5% rh
    Humidity active control (option K7) 40–97% rh and rh-Off
    Sterilization program 60 min at 180°C (sensors remain in place)
    Max. internals / load 12 shelves / 140 kg chamber / 15 kg per shelf
    Interface Ethernet LAN, USB
    Voltage / load 230V or 115V, 50/60Hz, approx. 1650 W
    Ambient operating temperature 10°C to 35°C
    Ambient humidity max. 70% rh, non-condensing
    Max. installation altitude 2,000 m above sea level
    Overvoltage category II
    Pollution degree 2
    Set-up clearance ≥15 cm rear, ≥20 cm ceiling, ≥5 cm sides
    Net / gross weight (with packaging) 110 kg / 145 kg approx.
    Packaging dimensions 840 x 1360 x 900 mm
    Country of origin Federal Republic of Germany
    Customs tariff number 8419 8998
    WEEE-Reg.-No. DE 66812464
    Safety approval Standard units are safety-approved and bear the test marks

    Standard equipment: works calibration certificate (chamber center, +37°C, 5% CO2 for standard units; +37°C, 5% CO2, 90% rh with option K7; +37°C, 5% CO2, 90% rh, 10% O2 with options K7+T6); fully insulated stainless steel door with 2-point compression lock; inner glass door with 8mm Ø gas sampling port; CO2 connection set (hose, coupling, clamp); membrane filter for incoming gas; 2 perforated stainless steel shelves; 1 stainless steel water dish.