Microbial air monitoring system that samples at 25l/min to comply with continuous monitoring of the new GMP Annex 1 in Grade A and B zones. Unit has 2 heads to be programmed to do sampling in relay to cover a longer critical process. Each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 2 s/s aspirating head (code 830) with s/s cover head (code 465), 1 cable for transfer data and 1 robustus carrying case
Genie PURIST ultrapure water system produces Type I ultrapure water from RO, distilled or deionized water and it is designed for critical laboratory applications, offering desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure water in the lab. Quality of ultrapure water meet or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via wired or wireless.
- An optional automatic system shut-off upon detection of any water leakage.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- A universal water level sensor can be provided to prevent the system from pumping air.
Effective TOC level controlment
- Built-in 185/254 nm dual wavelength lamp reduces TOC level in ultrapure water.
- On-line TOC monitor based on complete oxidation methods (for TOC models).
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. Cartridge
Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
A full range of cartridges for various applications including ultra-low TOC, low Mg, low boron, ICP and DI type.
2. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
The console screen and dispenser screens are water-frop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
3. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
4. Final Filter
Various final filters (optional) are applicable to ensure ultrapure water without particles, bacteria or pyrogen.
Microbial air monitoring system that samples at 25l/min to comply with continuous monitoring of the new GMP Annex 1 in Grade A and B zones. Unit has 3 heads to be programmed to do sampling in relay to cover a longer critical process. Each PACK consists of: 1 air sampler with Bluetooth and battery charger, 1 calibration certificate, 3 s/s aspirating head (code 830) with s/s cover head (code 465), 1 cable for transfer data and 1 robustus carrying case.
Genie A est un système d'eau de laboratoire prêt à l'emploi, peu encombrant, qui produit de l'eau ultra-pure (eau de type I) et de l'eau osmosée directement à partir de l'eau du robinet. Il constitue le choix idéal pour les utilisateurs qui ont besoin de jusqu'à 20 litres d'eau ultra-pure ou d'eau osmosée par jour.
La qualité de l'eau ultra-pure produite est conforme ou supérieure aux normes ASTM, CLSI, CAP et ISO de type I.
Conception & Fonctions
- L'appareil peut être relié à plusieurs distributeurs via un câble filaire ou sans fil.
- La compensation automatique de la température permet un débit de production RO stable sur une large plage de températures.
- Le système de contrôle entièrement automatisé comprend des fonctions de nettoyage, de rinçage, de vidange et bien d'autres encore.
- Il rince automatiquement une nouvelle membrane RO. L'utilisateur n'a pas besoin de définir un programme de rinçage spécial pour une nouvelle membrane RO.
- Si l'eau RO ne répond pas à une norme de qualité prédéfinie, une dérivation l'envoie automatiquement vers le drain. L'eau de drainage RO est réutilisée pour augmenter le rendement en eau, ce qui la rend plus respectueuse de l'environnement.
- Comme le système principal peut être fixé au mur, posé sur une étagère ou sous l'évier, il permet de gagner un espace précieux sur le plan de travail.
- Les fonctions de nettoyage au chlore et au pH facilitent l'entretien et garantissent une qualité d'eau optimale.
- Aucun réservoir de stockage n'est nécessaire, ce qui élimine le risque de contamination et de prolifération bactérienne lié au réservoir de stockage.
- Conception compacte : aucun filtre de prétraitement supplémentaire n'est nécessaire; distributeur à distance intégré au système.
- Le dispositif anti-fuites intégré permet d'éviter les dommages causés par une fuite d'eau en coupant l'alimentation en eau en cas de fuite imprévue.
Contrôle efficace du niveau de COT
- La lampe à double longueur d'onde intégrée de 185/254 nm réduit le niveau de COT dans l'eau ultra-pure.
- Moniteur COT en ligne basé sur des méthodes d'oxydation complète (pour les modèles COT).
Facilité d'utilisation et d'entretien
- L'historique des performances, les informations relatives aux alarmes et aux alertes, les données de maintenance des consommables et des pièces clés sont enregistrées et peuvent être consultées à partir d'un simple scan RFID lors de l'installation.
- Les balises RFID garantissent un placement parfait des consommables et permettent de suivre leurs performances.
- Le grand écran couleur a affiché les données relatives à la qualité de l'eau, aux paramètres de fonctionnement, à l'état du système, aux distributeurs, aux composants et aux périphériques.
- Vérification de signature pour la maintenance et le service.
Cartouches et Pièces
1. Cartouche
Le pack de préfiltration élimine la plupart des grosses particules, le chlore, le calcium ou les composés organiques afin de protéger la membrane RO et de prolonger sa durée de vie.
La cartouche d'ultra-purification est remplie de médias LeFilTM et OrganeFilTM pour éliminer les ions et les composés organiques à l'état de traces.
2. Console de commande
La console de 8 pouces contrôle le système et les périphériques (tels que le protecteur anti-fuites et le module de désinfection du réservoir). Toutes les opérations peuvent être effectuées sur la console en touchant l'écran.
La console de commande peut être placée sur la paillasse ou à l'intérieur d'un tiroir pour plus de flexibilité et un gain de place.
L'écran de la console et les écrans du distributeur sont résistants aux gouttes d'eau. Vous pouvez utiliser la console et le distributeur avec des gants en latex.
Pour des raisons de sécurité, le système dispose d'une protection par mot de passe à deux niveaux sur le menu d'affichage.
3. Distributeur
Une fois configurée, la fonction volumétrique peut fournir automatiquement le volume d'eau dont vous avez besoin.
Grâce au bouton de réglage situé sur la console de commande ou le distributeur, vous pouvez distribuer de l'eau au débit souhaité, jusqu'à 2 litres par minute.
La poignée du distributeur peut être placée sur le support du distributeur, sur le système principal ou même suspendue à d'autres endroits afin de libérer un maximum d'espace sur la paillasse.
4. Filtre Final
Une large gamme de filtres finaux (en option) est disponible pour garantir une eau ultra-pure sans particules, bactéries ou pyrogènes.
.
.
Genie E produces EDI water (Type II water) from tap water directly. Resistivity of the product water is above 5 MΩ•cm at 25 °C, which meets or exceeds Type II water quality as defined by ASTM, CAP, CLSI and ISO 3696 / BS 3997 and also complies with the purified water requirements from the European and U.S. Pharmacopoeia.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
- Exceptionally consistent and predictable high purity Type II water from the best-in-class EDI (electrodeionization) module.
- Stable RO permeability over a wide range of temperatures on account of a temperature stabilization feedback function of the module.
- An environmentally friendly In-line mercury-free germicidal UV lamp is applied to kill bacteria.
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in the event of unexpected leaking.
- Tank recirculation model guarantees water quality in the tank.
- Fully automated system has RO cleaning, pre-rinsing, flush and lots of other self-maintenance functions. The chlorine cleaning and pH cleaning functions make maintenance easier and ensure optimal water quality.
Effective TOC level controlment
- A tank sanitization module is equipped to effectively keep microbial growth at a lower level by LED UVC light.
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. EDI module
Internal EDI module removes the remaining ions, further reduces the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of energy.
2. Cartridge
Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
AC Pack contains specially activated carbon to remove organic impurities and free chlorines.
3. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space savings.
The console screen and dispenser screens are water-drop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
4. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
5. Final Filter
Various final filters (optional) are applicable to ensure ultrapure water without particles, bacteria or pyrogen.
6. Level sensor
The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
Water level and quality inside the tank can be viewed from the control console.
Including:
1x TRIO.BAS MINI BLUETOOTH Air sampler (100 lts/min) Petri 90 plate with Battery charger 100/240VCA 18VDC 859 mA - cable with adapter for plug Eu/UK/USA - and 1 calibration certificate
1x s/s ASPI HEAD Petri plate
1x COVER HEAD s/s to protect ASPI HEAD
1x LIGHT STANDARD carrying case - 43x35x19h cm
Genie R produces reverse osmosis (RO) laboratory-grade water from tap water directly. It applies high recovery reverse osmosis (RO) technology to produce pure water for general laboratory needs with easy maintenance and low running costs. Genie R offers desired solutions for research professionals who work with a variety of applications utilizing RO pure water in the lab.
The system is CE/RoHS certified. RephiLe provides full document support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via wired or wireless. “1+N” Mode.
- Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
- Fully automated control system has cleaning, rising, flush and many other functions.
- System automatically rinses a new RO membrane. User does not need to set special rinse program for a new RO membrane.
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- The Chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
- Leak protector is incorporated inside to shut the feed water off to prevent damage from leakage.
- A tank sanitization module can be used to effectively keep microbial growth at a lower level by LED UVC light.
- Tank recirculation model guarantees water quality in the tank.
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. Cartridge
Pre-filtration pack removes most large particles, chlorine, calcium or organic compounds to protect RO membrane to extend their usable life.
AC Pack contains special activated carbon to remove organic impurities and free chlorines.
2. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
The console screen and dispenser screens are water-drop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
3. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
4. Level sensor
The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
Water level and quality inside the tank can be viewed from the control console.
Specifications:
- ULPA Filter
- ISO Class 3 work zone
- DC ECM blower for up to 70% energy savings
- Low noise at 55.8 dBA
- Glass side walls
- Fixed Sash
Including:
1x TRIO.BAS MONO BLUETOOTH Air sampler (100 lts/min) Petri 90 plate with Battery charger 100/240VCA 18VDC 859 mA with adapter for plug Eu/UK/USA - and CABLE for transfer data and 1 calibration certificate
1x s/s ASPI HEAD Petri plate
1x COVER HEAD s/s to protect ASPI HEAD
1x ROBUSTUS STANDARD carrying case - 48x38x17h cm
Genie G produces ultrapure water (Type I water) and EDI water (Type II water) from tap water directly. It offers desired solutions for research professionals who work with a variety of applications utilizing Type I ultrapure and Type II pure water in the lab. Quality of ultrapure water and EDI water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water and Type II water standards, respectively.
The system is CE/RoHS certified. RephiLe provides full document support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
- Exceptionally consistent and predictable high purity Type II water from the best-in-class EDI (electrodeionization) module.
- Stable RO permeability over a wide range of temperatures on account of a temperature stabilization feedback function of the module.
- An environmentally friendly In-line Mercury-free germicidal UV lamp is applied to kill bacteria.
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in the event of unexpected leak.
- Tank recirculation model guarantees water quality in the tank.
- Fully automated system has RO cleaning, pre-rinsing, flush and lots of other self-maintenance functions. The chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
Effective TOC level control
- A 185/254 nm dual wavelength UV lamp reduces TOC level in ultrapure water.
- A tank sanitization module is equipped to effectively keep microbial growth at a lower level by LED UV light.
- On-line TOC monitoring is based on complete oxidation methods.
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. EDI module
- Internal EDI module removes the remaining ions, further reduces the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
- Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
- EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of energy.
2. Cartridge
- Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
- AC Pack contains special activated carbon to remove organic impurities and free chlorines.
- Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
3. Control console
- 8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
- The control console can be placed on the bench or inside a drawer for further flexibility and space savings.
- The console screen and dispenser screens are water-drop proof. You can operate the console and dispenser with latex gloves on.
- The system has two level password protection on display menu for safety purposes.
4. Dispenser
- The volumetric function can automatically deliver the water volume you need once it is set up.
- With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
- A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
5. Final Filter
- A wide range of final filters (optional) is applicable to ensure ultrapure water without particles, bacteria or pyrogen.
6. Level sensor
- The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
- Water level and quality inside the tank can be viewed from the control console.
Where on-site liquid nitrogen is essential
- Cryopreservation and biobanking
- NMR systems
- Cryogenic GC applications
- Medical and laboratory cooling workflows
Key features
- On-site LN₂ production (up to 80 L/day)
- Integrated air compressor and dewar tank
- Cryogenic liquefaction at –196.76 °C
- PSA separation with CMS technology
- Touchscreen control with real-time monitoring
- Automatic level control and safe dispensing
Spécifications:
- Filtre ULPA
- Zone de travail ISO classe 3
- Ventilateur DC ECM pour une économie d'énergie pouvant atteindre 70 %
- Faible niveau sonore de 55,8 dBA
- Parois latérales en verre
- Fenêtre coulissante fixe
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie