- Analytische chemie
- Beschermingskasten
- Biologische beeldvorming
- Bloedplaatjesaggregatie
- Capillaire elektroforese
- Celculturen en fermentatie
- Cellulaire analyse
- Centrifugatie
- Chromatografie (flash & prep)
- DNA / RNA (nucleïnezuren)
- Deeltjeskarakterisatie
- Desinfectie
- Elektrochemie
- Flowcytometrie
- Flowcytometrie celsorting
- Geautomatiseerde Liquid Handling
- Hematologie
- Immuno-hematologie
- Immunodosage
- In-vitrofertilisatie (IVF)
- Kleur-Appearance en fysische testen
- Klinische IT-oplossingen
- Klinische automatisering (TLA)
- Klinische chemie
- Klinische kwaliteitscontroles
- Laboratoriummeubilair & ontwerpstudies
- Massaspectrometers
- Materiaaltesten en -karakterisering
- Metrologie
- Microbiologie (Klinische)
- Microscopie
- Monstersvoorbereiding
- Nefelometrie
- Omgevingscontrole
- Opslag
- POCT
- Pipetteren van vloeistoffen (handmatig)
- Pompen
- Reinigen
- Reometers
- Shakers and stirrers
- Sterilisatie
- Synthese
- Tablet testing
- Texturometers
- Thermische analyse
- Toxicologie
- Urineanalyse
- Verwarmen & koelen
- Viscometers
- Vochtanalyse
- Vriesdrogen
- Waterzuivering
- Wegen
- Microscopie Microscopen voor materiaalwetenschappen
- Linkam Optical Differential Scanning Calorimetry
HOME / APPLICATIONS & TECHNIQUES /
Linkam Optical Differential Scanning Calorimetry
Referentie: LINK-DSC450
https://www.analis.com/shop/link-dsc450-linkam-optical-differential-scanning-calorimetry-148219 https://www.analis.com/web/image/product.template/148219/image_1920?unique=ad3a0d8The Linkam Optical DSC450 is a DSC and microscope for thermal and glass transition measurements. It combines Differential Scanning Calorimetry (DSC) with light microscopy, which provides a wealth of information for characterizing polymers, pharmaceuticals and other materials.
The DSC stage mounts on a microscope, enabling high-resolution image and time recording of sample transitions. The system includes a T96 controller, LINK software and optional Digital Imaging and Thermal Analysis by Structural Characterization (TASC) modules.
Key Advantages at a Glance
- Highly sensitive and accurate, with thermal transitions measured at low heating rates or with small sample sizes without loss of sensitivity and accuracy
- Wide temperature range from -150 °C to 450 °C; the optional LNP96-S is needed for low temperatures
- Simultaneous imaging and DSC analysis with the Linkam Imaging Station, optimized for the Linkam stage; the measurement chamber lid has a silica window for capturing and recording images
- Optional TASC module (developed with Cyversa) that tracks changes in surface structure and shows glass and melting transitions with high accuracy
- Analysis of different areas of the same sample to identify inhomogeneity
- Modular thermal analysis system: TASC can be combined with any Linkam thermal stage
- Sealed crucible available for closed-pan (cup-lid) experiments
Suitable For
The DSC450 is suited to measuring and imaging glass transitions and melting peaks for many applications, including:
- Measurement and imaging of glass transitions and melting peaks
- Materials
- Pharmaceutical products
- Food
Ask Analis' local Benelux experts for more information, a demonstration, or a personalized quote.
Technische Informatie
Category | Specification |
Temperature range | -150 °C to 450 °C |
Heating / cooling | 0.01 °C to 30 °C/min |
Stability | <0.1 °C |
Lens working distance | 9.7 mm |
Sample pans | Aluminium and sapphire |
Furnace lid | Sapphire or silver |
TASC
The TASC Image Analysis module is an optional module that offers new thermal analysis systems. Linkam and Cyversa have entered into a collaboration and developed a thermal technique for analyzing materials.
- Turn your temperature-controlled microscope stage into a thermal analysis laboratory suitable for measuring glass and melting transitions in many different materials, including opaque samples.
- More sensitive than standard DSC at low heating rates and for small samples.
- Kinetic parameters over a wider range of heating rates than conventional methods.
- Thermal analysis on specified areas (local).
Related Stages and Accessories
- LNP96 nitrogen cooler available for temperatures down to -180 °C
- Microscope hot stages available for temperatures between -196 °C and 1500 °C
- Linkam TST350 Tensile Stage enables tensile tests up to 200 N at temperatures from 196 °C to 350 °C under a controlled gas atmosphere; microscope images are recorded during the measurement
- Humidity generator controls relative humidity between 10 and 90% up to 85 °C
Beschermingskasten
Biologische beeldvorming
Bloedplaatjesaggregatie
Capillaire elektroforese
Celculturen en fermentatie
Cellulaire analyse
Centrifugatie
Chromatografie (flash & prep)
DNA / RNA (nucleïnezuren)
Deeltjeskarakterisatie
Desinfectie
Elektrochemie
Flowcytometrie
Flowcytometrie celsorting
Geautomatiseerde Liquid Handling
Hematologie
Immuno-hematologie
Immunodosage
In-vitrofertilisatie (IVF)
Kleur-Appearance en fysische testen
Klinische IT-oplossingen
Klinische automatisering (TLA)
Klinische chemie
Klinische kwaliteitscontroles
Laboratoriummeubilair & ontwerpstudies
Massaspectrometers
Materiaaltesten en -karakterisering
Metrologie
Microbiologie (Klinische)
Microscopie
Monstersvoorbereiding
Nefelometrie
Omgevingscontrole
Opslag
POCT
Pipetteren van vloeistoffen (handmatig)
Pompen
Reinigen
Reometers
Shakers and stirrers
Sterilisatie
Synthese
Tablet testing
Texturometers
Thermische analyse
Toxicologie
Urineanalyse
Verwarmen & koelen
Viscometers
Vochtanalyse
Vriesdrogen
Waterzuivering
Wegen