Systec VX-150
Reference: SYS-1150
https://www.analis.com/shop/sys-1150-systec-vx-150-23199 https://www.analis.com/web/image/product.template/23199/image_1920?unique=81ce7adThe Systec V-Series of top-loading vertical autoclaves in 8 different sizes with 40 to 150 liters chamber volume is distinguished by its small footprint and high chamber capacity. Result: optimal loading capacity with most standard media bottles and Erlenmeyer flasks.
Systec VX-150 Vertical, top-loading autoclave,
Chamber volume (liter) total /nominal: 166/150,
Chamber dimensions (mm) Ø x depth: 500 x 750.
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Technical information
Connections:
- Electrical connections: 220 - 240 V
- Demineralized water: 3/4" stopcock for tube connection
(only necessary for automatic filling. Water can also be filled manually prior to a sterilisation program)
- Process water (tap water): 3/4" stopcock for tube connection
(only necessary for steam exhaust condensation. Unit can also run without tap water if condensation is not necessary)
- Drain: 3/4" tube connection; max. 400 mm from floor or floor drain (siphon)