No more need to mount capillaries. Pre-assembled EZ-CE cartridge (part # A55625) for multiple applications (Purity Analysis, Rapid Charge Variant Analysis, and Fast Glycan Analysis)
> Precision cut tips – ensure uniformity of injection plug from capillary to capillary
> Alignment precision at window – reduces potential failure due to misalignment
> Reduce preparation time for operator – simplifying the process and training requirements
Capillaries must be trimmed to optimize speed/resolution.
This capillary is used with the Carbohydrate Labeling and Analysis Kit.
Reorder component for P/N 477600.
eCAP™ Neutral Coated Capillary with laser burned window - 50 µm ID x 67 cm total length.
Capillary used with the Advanced cIEF Starter Kit (Part number A80976).
Capillaries must be trimmed to optimize for speed/resolution.
This capillary is also suitable for other applications where no EOF is desired. Thanks to the polyacrylamide coating, no EOF is present. The capillary can be used with both UV and LIF detection systems but capillary life is impacted when used with diodearray detection systems.
Quartz sample boats to be used with Milestone DMA-80 evo direct mercury analyser
De roterende vacuümconcentrator RVC 2-18 CDplus, 230 V, 50/60 Hz (tafelmodel) is een standaardversie met roestvrijstalen rotorkamer, magnetisch aandrijfsysteem, verwarmde rotorkamer (240 W), deksel met kijkvenster, elektrische vergrendeling en veiligheidsvoorziening. Gebruiksvriendelijk besturingssysteem met LC-display.
Sensorcassette voor het snelle en efficiënte Vi-CELL MetaFLEX Bioanalyze-platform.
De Vi-CELL MetaFLEX-sensorcassette bevat sensoren voor de tests (behalve voor de oximetrie- en bilirubinetests). Deze maakt gebruik van de dikkefilm-sensortechnologie en geminiaturiseerde sensoren om directe metingen van glucose en lactaat uit een monster van 100 μL (65μL-monster plus 35μL- tarra) mogelijk te maken.
De SC300 meet pH, pO2, pCO2, glucose, lactaat en elektrolyten in een celkweekmedium en ook meer parameters m.b.t. de analyse van volbloed.
.
SDS-MW Gel Buffer is a 4-pack of the SDS-MW gel used in the SDS-MW Kit (Part Number 390953) and the IgG Purity and Heterogeneity Kit Assay (Part Number A10663).
SDS-MW gel designed for the separation and sizing of protein samples, utilizing SDS complexes as a replaceable gel matrix.
De SDS-Gel MW-analysekit is ontworpen voor de scheiding en kwantificering van eiwit-SDS-complexen m.b.v. een vervangbare gelmatrix. De gel is zo samengesteld dat deze een effectief eiwitzeefbereik van ongeveer 10 tot 225 kDa biedt. Binnen dit groottebereik is de logaritme van de moleculaire massa van het eiwit lineair met de reciproke elektroforetische mobiliteit. Zo kan het molecuulgewicht van een onbekend eiwit worden geschat a.d.h.v. een standaardcurve van bekende eiwitgroottes. Deze chemie kan ook worden gebruikt om de hoeveelheid eiwit effectief te kwantificeren en de zuiverheid van een eiwitproduct te bepalen.
Inhoud:
• Scheidingscapillair, 57 cm x 50 µm ID, ongecoat gesmolten silica, (2)
• SDS-gelseparatiebuffer, 140 ml
• SDS-monsterbuffer, 100 mM Tris-HCl, pH 9,0/1% SDS, 50 ml
• SDS-eiwitgroottestandaard (10 tot 225 kDa), 16 mg/ml, 100 µl
• Interne standaard, 10 kDa-eiwit, 5 mg/ml, 0,4 ml
• Zure wasoplossing, 0,1 N HCl, 100 ml
• Basische wasoplossing, 0,1 N NaOH, 100 ml
• SDS-gel MW-analysegids (1)
Loading Solution for DNA sequencing and fragment analysis samples
This vacuum grease is for o-ring lubrification. Lubrification will protect the o-ring and maintain efficiency of the closure systems.
Silicon vacuum grease is used on the O-rings of centrifuges and ultracentrifuges to:
- Prevent Sample Spillage and contamination:
The grease helps maintain a tight seal, preventing any sample from leaking out and ensuring no contaminants enter the system. - Maintain Vacuum:
In devices like ultracentrifuges that operate under vacuum, the grease helps maintain the vacuum conditions by preventing air leaks into the centrifuge vessel. This is crucial for the proper functioning of these machines.
Set of 50x coated slides with one circle for use in Shandon & RESOSPIN® configurations of Sigma 2-7 Cytocentrifuges
946-mL bottles of Solution 555™ Rotor Cleaning Concentrate, 1 qty; minimum order 2 bottles.
Under normal use, as part of the day-to-day care and maintenance program of the centrifuge rotors, wash the rotor frequently to prevent the build-up of residues.
Beckman Solution 555 (339555) is a mild and efficient detergent that won’t damage the rotors.
Beschermingskasten
Biologische beeldvorming
Bloedplaatjesaggregatie
Capillaire elektroforese
Celculturen en fermentatie
Cellulaire analyse
Centrifugatie
Chromatografie (flash & prep)
DNA / RNA (nucleïnezuren)
Deeltjeskarakterisatie
Desinfectie
Elektrochemie
Flowcytometrie
Flowcytometrie celsorting
Geautomatiseerde Liquid Handling
Hematologie
Immuno-hematologie
Immunodosage
In-vitrofertilisatie (IVF)
Kleur-Appearance en fysische testen
Klinische IT-oplossingen
Klinische automatisering (TLA)
Klinische chemie
Klinische kwaliteitscontroles
Laboratoriummeubilair & ontwerpstudies
Massaspectrometers
Materiaaltesten en -karakterisering
Metrologie
Microbiologie (Klinische)
Microscopie
Monstersvoorbereiding
Nefelometrie
Omgevingscontrole
Opslag
POCT
Pipetteren van vloeistoffen (handmatig)
Pompen
Reinigen
Reometers
Shakers and stirrers
Sterilisatie
Synthese
Tablet testing
Texturometers
Toxicologie
Urineanalyse
Verwarmen & koelen
Viscometers
Vochtanalyse
Vriesdrogen
Waterzuivering
Wegen