No more need to mount capillaries. Pre-assembled EZ-CE cartridge (part # A55625) for multiple applications (Purity Analysis, Rapid Charge Variant Analysis, and Fast Glycan Analysis)
> Precision cut tips – ensure uniformity of injection plug from capillary to capillary
> Alignment precision at window – reduces potential failure due to misalignment
> Reduce preparation time for operator – simplifying the process and training requirements
Capillaries must be trimmed to optimize speed/resolution.
This capillary is used with the Carbohydrate Labeling and Analysis Kit.
Reorder component for P/N 477600.
eCAP™ Neutral Coated Capillary with laser burned window - 50 µm ID x 67 cm total length.
Capillary used with the Advanced cIEF Starter Kit (Part number A80976).
Capillaries must be trimmed to optimize for speed/resolution.
This capillary is also suitable for other applications where no EOF is desired. Thanks to the polyacrylamide coating, no EOF is present. The capillary can be used with both UV and LIF detection systems but capillary life is impacted when used with diodearray detection systems.
Quartz sample boats to be used with Milestone DMA-80 evo direct mercury analyser
Rotational-vacuum-concentrator RVC 2-18 CDplus, 230 V, 50/60 Hz standard version, bench top unit, stainless steel rotor chamber, magnetic drive system, heated rotor chamber (240 W), lid with inspection window and electrical locking- and safety device, user-friendly control system with LC display,
Sensor cassette for the fast and efficient Vi-CELL MetaFLEX Bioanalyze platform.
The Vi-CELL MetaFLEX sensor cassette contains sensors for the tests (except for the oximetry and bilirubin tests). It uses thick-film sensor technology and miniaturized sensors to enable direct measurements of glucose and lactate from a 100 μL sample (65 μL sample plus 35 μL tare).
SC300 measures pH, pO2, pCO2, Glucose, Lactate, Electrolytes in cell culture medium and also more parameters associated with whole blood analysis.
The SDS-Gel MW Analysis Kit is designed for the separation and sizing of protein–SDS complexes using a replaceable gel matrix. The gel is formulated to provide an effective protein sieving range of approximately 10 to 225 kDa. Within this size range, the logarithm of protein molecular mass is linear with its reciprocal electrophoretic mobility, allowing the molecular weight of an unknown protein to be estimated from a standard curve of known protein sizes. This chemistry can also be used to effectively quantify the amount of protein and to determine the purity of a protein product.
This includes:
• Separation Capillary, 57 cm x 50 µm ID, bare fused-silica, (2)
• SDS Gel Separation Buffer, 140 mL
• SDS Sample Buffer, 100 mM Tris-HCl, pH 9.0/1% SDS, 50 mL
• SDS Protein Sizing Standard (10 to 225 kDa), 16 mg/mL, 100 µL
• Internal Standard, 10 kDa protein, 5 mg/mL, 0.4 mL
• Acidic Wash Solution, 0.1 N HCl, 100 mL
• Basic Wash Solution, 0.1 N NaOH, 100 mL
• SDS-Gel MW Analysis Guide (1)
SDS-MW Gel Buffer is a 4-pack of the SDS-MW gel used in the SDS-MW Kit (Part Number 390953) and the IgG Purity and Heterogeneity Kit Assay (Part Number A10663).
SDS-MW gel designed for the separation and sizing of protein samples, utilizing SDS complexes as a replaceable gel matrix.
Loading Solution for DNA sequencing and fragment analysis samples
This vacuum grease is for o-ring lubrification. Lubrification will protect the o-ring and maintain efficiency of the closure systems.
Silicon vacuum grease is used on the O-rings of centrifuges and ultracentrifuges to:
- Prevent Sample Spillage and contamination:
The grease helps maintain a tight seal, preventing any sample from leaking out and ensuring no contaminants enter the system. - Maintain Vacuum:
In devices like ultracentrifuges that operate under vacuum, the grease helps maintain the vacuum conditions by preventing air leaks into the centrifuge vessel. This is crucial for the proper functioning of these machines.
Set of 50x coated slides with one circle for use in Shandon & RESOSPIN® configurations of Sigma 2-7 Cytocentrifuges
946-mL bottles of Solution 555™ Rotor Cleaning Concentrate, 1 qty; minimum order 2 bottles.
Under normal use, as part of the day-to-day care and maintenance program of the centrifuge rotors, wash the rotor frequently to prevent the build-up of residues.
Beckman Solution 555 (339555) is a mild and efficient detergent that won’t damage the rotors.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing