Fully Automatic Crude and Detergent Fiber

VELP FIWE ADVANCE Automatic Fiber Analysis of Crude or detergent fiber

Accurate and reproducible results are what a scientist of the animal feed industry needs for fiber determinations to meet the requirements of product labeling and quality control.

The FIWE Advance automates digestionwashing and filtration steps guaranteeing consistency for Crude Fiber with Weende Method and Detergent Fiber for fiber fraction with Van Soest Method NDF, ADF and ADL.

Compliance and consistency

Complience and Consistency in fiber analysis VELP FIWE ADVANCE Automatic Fiber Analysis

FIWE Advance produces accurate results that always comply with official ISO and AOAC methods for both Crude Fiber and Detergent Fiber.

In addition, the FIWE Advance method using crucibles avoids the loss of fibre due to the transfer of the sample which remains in the crucible for the duration of the analytical procedure.

The sample in fact remains inside the crucibles during the extraction, digestion, washing and filtration phases, and also during weighing and finally for drying and ashing eliminating the risks of error.

Load the samples and go

Load the samples and go VELP FIWE Advance saves time by reducing costs and improving lab productivity

FIWE Advance saves you valuable time by reducing costs and improving your lab's productivity.

FIWE Advance requires only 2 minutes of operator time compared to more than 50 minutes/operator of a semi-automatic solution.

You will no longer need to preheat and pour chemicals into the columns, manage the temperature for proper boiling, or make sure the filtration is successful.

With FIWE Advance all these operations are automatic and thanks to the cloud connection you are always informed with immediate notifications.

    This combination does not exist.

    Données Techniques

    Positions / Number of samples

    Up to 6 samples

    Capacity per day

    Up to 36 (Crude Fiber / Wendee Method)
    Up to 60 (Other methods)

    Samples

    Individually processed

    Sample quantity

    From 0,5 to 3 g

    Display

    7” color touch screen

    Measurement Range

    0.1-100%

    Repeatability

    ± 1% relative at 5%-30% fiber amount

    Lighting

    LED lights show active positions

    Level of automation

    Fully automated

    Heating and dispensing of reagents

    Automatic

    Reagent pre-heating time

    5 - 7 min

    Time from preheated temperature to boiling

    5 - 10 min

    Connectivity

    Cloud via LAN or USB Wi-Fi adapter (accessory)

    Interfaces

    3 x USB (balance, barcode scanner, mouse, USB stick, USB Wi-Fi Adapter), Ethernet (Pc)

    Result Calculation

    Automatic, On-board archive for data storage

    Protocol library

    5 standard methods + 30 customizable methods

    Water Consumption

    from 1.0 l/min

    Dimension (WxDxH)

    735 x 420 x 666 mm (28,9 x 16,5 x 26,2 in)

    Weight

    57 Kg (125 lb)

    Power Supply

    230 – 50/60 V-Hz

    Power Consumption

    2100 W


    Documents connexes

    NOM DU DOCUMENT

    DATE DE SORTIE

    TÉLÉCHARGER

    VELP-Brochure-FIWE Advance
    23 / 12 / 2024

    Accessoires, consommables et produits connexes

    FIWE 6 Fiber Analyzer
    VELP

    FIWE 6 Fiber Analyzer

    Reference : VEL-SA30520200

    Crude Fiber, Neutral & Acid Detergent Fiber

    VELP FIWE 3 - FIWE 6 Automatic Fiber Analyzer for Crude Fiber or Neutral and Acid Detergent Fiber

    FIWE 3 and FIWE 6 are fiber analyzers suitable for raw fiber extraction, conventionally known as an indigestible residue. Rapid analysis, reliable results and high reproducibility are some of the most relevant benefits of these units which are ideal for the following applications:

    • the Weende method, the oldest analytical procedure still in use today, in which fiber concentration is measured as crude fiber (CF)
    • the Neutral Detergent Fiber (NDF), a method developed by Van Soest, now the most common measure of fiber used for animal feed analysis
    • Acid Detergent Fiber (ADF), a portion of the plant fiber and includes cellulose, lignin and variable amounts of xylans.
    • Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of the Weende method

    High Reliability, Single or Multiple Extractions

    Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.
    No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.
    Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.

    No transfer and sample loss

    VELP COEX rapid fat extraction to prepare sample for fiber analysis

    In order to prepare the sample for fiber analysis, COEX ensures rapid fat extraction directly into the same glass crucibles used by the FIWE series.

    The crucible, containing the defatted sample, is transferred directly to the FIWE analyzer, eliminating.

    FIWE 3 Fiber Analyzer
    VELP

    FIWE 3 Fiber Analyzer

    Reference : VEL-SA30520201

    Crude Fiber, Neutral & Acid Detergent Fiber

    VELP FIWE 3 - FIWE 6 Automatic Fiber Analyzer for Crude Fiber or Neutral and Acid Detergent Fiber

    FIWE 3 (like the FIWE 6) is a fiber analyzer suitable for raw fiber extraction, conventionally known as an indigestible residue. Rapid analysis, reliable results and high reproducibility are some of the most relevant benefits of these units which are ideal for the following applications:

    • the Weende method, the oldest analytical procedure still in use today, in which fiber concentration is measured as crude fiber (CF)
    • the Neutral Detergent Fiber (NDF), a method developed by Van Soest, now the most common measure of fiber used for animal feed analysis
    • Acid Detergent Fiber (ADF), a portion of the plant fiber and includes cellulose, lignin and variable amounts of xylans.
    • Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of the Weende method

    High Reliability, Single or Multiple Extractions

    Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.
    No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.
    Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.

    No transfer and sample loss

    VELP COEX rapid fat extraction to prepare sample for fiber analysis

    In order to prepare the sample for fiber analysis, COEX ensures rapid fat extraction directly into the same glass crucibles used by the FIWE series.

    The crucible, containing the defatted sample, is transferred directly to the FIWE analyzer, eliminating.