Se rendre au contenu
VELP

FIWE 6 Fiber Analyzer

Référence: VEL-SA30520200

https://www.analis.com/web/image/product.template/123383/image_1920?unique=9c80963

Crude Fiber, Neutral & Acid Detergent Fiber

VELP FIWE 3 - FIWE 6 Automatic Fiber Analyzer for Crude Fiber or Neutral and Acid Detergent Fiber

FIWE 3 and FIWE 6 are fiber analyzers suitable for raw fiber extraction, conventionally known as an indigestible residue. Rapid analysis, reliable results and high reproducibility are some of the most relevant benefits of these units which are ideal for the following applications:

  • the Weende method, the oldest analytical procedure still in use today, in which fiber concentration is measured as crude fiber (CF)
  • the Neutral Detergent Fiber (NDF), a method developed by Van Soest, now the most common measure of fiber used for animal feed analysis
  • Acid Detergent Fiber (ADF), a portion of the plant fiber and includes cellulose, lignin and variable amounts of xylans.
  • Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of the Weende method

High Reliability, Single or Multiple Extractions

Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.
No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.
Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.

No transfer and sample loss

VELP COEX rapid fat extraction to prepare sample for fiber analysis

In order to prepare the sample for fiber analysis, COEX ensures rapid fat extraction directly into the same glass crucibles used by the FIWE series.

The crucible, containing the defatted sample, is transferred directly to the FIWE analyzer, eliminating.

    This combination does not exist.

    Données Techniques

    Construction material:

    epoxy painted stainless steel structure

    Type of extractions:

    cold and hot extractions

    Number of samples:

    FIWE 3 3 positions
    FIWE 6 6 positions

    Samples:

    individually processed

    Sample quantity:

    from 0,5 to 3 g

    Reproducibility (RSD):

    ± 1%

    Sample removal:

    air pump

    Reagent discharge:

    peristaltic pump

    Digital timer:

    0 - 99 minutes with acoustic signal at the end

    Temperature:

    electronic regulation

    Reagents and cooling water :

    separated outlets

    Power:

    FIWE 3 900 W
    FIWE 6 1200 W

    Weight:

    FIWE 3 35 Kg (77 lb)
    FIWE 6 40 Kg (101.2 lb)

    Dimensions (WxHxD):

    FIWE 3 530x620x390 mm (20.9x24.4x15.4 in)
    FIWE 6 760x620x390 mm (29.5x24.4x15.4 in)

    Applications

    Raw fiber (Weende, Wijstrom)
    Neutral or acid detergent treatment fiber (Van Soest)
    Lignin, Cellulose, Hemicellulose

    Documents connexes

    NOM DU DOCUMENT

    DATE DE SORTIE

    TÉLÉCHARGER

    VELP-Brochure-FIWE
    23 / 12 / 2024

    Accessoires, consommables et produits connexes

    FIWE Advance Automatic Fiber Analyzer
    VELP

    FIWE Advance Automatic Fiber Analyzer

    Reference : VEL-F30500500

    Fully Automatic Crude and Detergent Fiber

    VELP FIWE ADVANCE Automatic Fiber Analysis of Crude or detergent fiber

    Accurate and reproducible results are what a scientist of the animal feed industry needs for fiber determinations to meet the requirements of product labeling and quality control.

    The FIWE Advance automates digestionwashing and filtration steps guaranteeing consistency for Crude Fiber with Weende Method and Detergent Fiber for fiber fraction with Van Soest Method NDF, ADF and ADL.

    Compliance and consistency

    Complience and Consistency in fiber analysis VELP FIWE ADVANCE Automatic Fiber Analysis

    FIWE Advance produces accurate results that always comply with official ISO and AOAC methods for both Crude Fiber and Detergent Fiber.

    In addition, the FIWE Advance method using crucibles avoids the loss of fibre due to the transfer of the sample which remains in the crucible for the duration of the analytical procedure.

    The sample in fact remains inside the crucibles during the extraction, digestion, washing and filtration phases, and also during weighing and finally for drying and ashing eliminating the risks of error.

    Load the samples and go

    Load the samples and go VELP FIWE Advance saves time by reducing costs and improving lab productivity

    FIWE Advance saves you valuable time by reducing costs and improving your lab's productivity.

    FIWE Advance requires only 2 minutes of operator time compared to more than 50 minutes/operator of a semi-automatic solution.

    You will no longer need to preheat and pour chemicals into the columns, manage the temperature for proper boiling, or make sure the filtration is successful.

    With FIWE Advance all these operations are automatic and thanks to the cloud connection you are always informed with immediate notifications.

    FIWE 3 Fiber Analyzer
    VELP

    FIWE 3 Fiber Analyzer

    Reference : VEL-SA30520201

    Crude Fiber, Neutral & Acid Detergent Fiber

    VELP FIWE 3 - FIWE 6 Automatic Fiber Analyzer for Crude Fiber or Neutral and Acid Detergent Fiber

    FIWE 3 (like the FIWE 6) is a fiber analyzer suitable for raw fiber extraction, conventionally known as an indigestible residue. Rapid analysis, reliable results and high reproducibility are some of the most relevant benefits of these units which are ideal for the following applications:

    • the Weende method, the oldest analytical procedure still in use today, in which fiber concentration is measured as crude fiber (CF)
    • the Neutral Detergent Fiber (NDF), a method developed by Van Soest, now the most common measure of fiber used for animal feed analysis
    • Acid Detergent Fiber (ADF), a portion of the plant fiber and includes cellulose, lignin and variable amounts of xylans.
    • Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of the Weende method

    High Reliability, Single or Multiple Extractions

    Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.
    No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.
    Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.

    No transfer and sample loss

    VELP COEX rapid fat extraction to prepare sample for fiber analysis

    In order to prepare the sample for fiber analysis, COEX ensures rapid fat extraction directly into the same glass crucibles used by the FIWE series.

    The crucible, containing the defatted sample, is transferred directly to the FIWE analyzer, eliminating.