- ADN / ARN (acides nucléiques)
- Agitateurs et shakers
- Agrégation plaquettaire
- Analyse cellulaire
- Analyse de l'humidité
- Analyse urinaire
- Caractérisation des particules
- Centrifugation
- Chauffage et refroidissement
- Chimie analytique
- Chimie clinique
- Chromatographie flash & préparative
- Contrôle environnemental
- Contrôles de qualité cliniques
- Couleur-Apparence et tests physiques
- Culture cellulaire et fermentation
- Cytométrie en flux
- Désinfection
- Electrophorèse capillaire
- Enceintes de Protection
- Essais de matériaux
- Fécondation in vitro (FIV)
- Hématologie
- Imagerie biologique
- Immuno-hématologie
- Immunoassay
- Lyophilisation
- Microbiologie (clinique)
- Microscopie
- Mobilier de laboratoire et études de conception
- Métrologie
- Nephelometry (Néphélométrie)
- Nettoyage Lavage
- POCT
- Pesage
- Pipetage de liquides (manuel)
- Pompes
- Préparation d'échantillon
- Purification de l'eau
- Robot de pipetage
- Solutions d'automatisation clinique (TLA)
- Solutions informatiques cliniques
- Spectromètres de masse
- Stockage
- Stérilisation
- Synthèse
- Tests sur tablettes
- Texturomètres
- Toxicologie
- Tri cellulaire par Cytométrie en flux
- Viscosimétrie
- Électrochimie
- Essais de matériaux Stabilité à l'oxydation
- OXITEST Oxidation Stability Reactor
HOME / APPLICATIONS & TECHNIQUES /
OXITEST Oxidation Stability Reactor
Référence: VEL-F30900248
https://www.analis.com/shop/vel-f30900248-oxitest-oxidation-stability-reactor-123386 https://www.analis.com/web/image/product.template/123386/image_1920?unique=689d05dFats and oils oxidation stability tests for R&D and QC Labs
The oxidation stability tests performed with the OXITEST reactor accelerate the lipid's oxidation process that in normal conditions can last weeks or months and provide fast, accurate and reliable results for Food & Feed, Cosmetic, Pharma and Petrochemical industries.
The OXITEST provides added value information for Quality Control and Research & Development Labs for:
- Quality control of raw materials and ingredients
- Transportation and effects on goods
- Storage period studies
- Product Development and behavior
- Formula Optimization
- Ingredient and alternative ingredients testing
- Process optimization
- Packaging study and alternative packaging comparison
The results of the OXITEST are expressed through the IP Induction Period.
The IP is the time required to reach the starting point of oxidation, corresponding to either a level of detectable rancidity or a sudden change in the rate of oxidation.
The longer the Induction Period, the higher the stability against oxidation over time.
Representative results testing the whole sample
The OXITEST reactor subjects the sample to a high oxidative stress environment in order to evaluate, in a short period of time, the resistance to fat oxidation:
- Established over-pressure of pure oxygen (6 bar, degree 5.0)
- High constant temperature, 90 °C
With the OXITEST Method, the stability test is performed directly on the sample as it is solid, liquid or doughy.
The method's key advantage is that the OXITEST ensures representative results without extensive sample preparation.
Other components of the sample matrix such as chemical oxidants or transition metal can promote oxidation and the use of extracted matter may not be a suitable predictor of stability.
OXISoft™ software powerful and intuitive
The OXITEST is entirely controlled via PC through the intuitive OXISoftTM software which is able to control up to 4 OXITEST simultaneously and independently. The OXISoft™ is quick and easy-to-use, at a glance you always have the program parameters, work conditions and results.
The software comes with multi-lingual support and a pre-installed library of methods related to a wide range of sample types, you can use these, modify them and create your own methods!
Data management, reportiing and archive with the following test types:
- Repeatability test
- Freshness test
- Formulas comparison
- Packaging comparison
- IP during ageing
- Estimated shelf life
Données Techniques
|
Number of oxidation chambers: |
2 |
|
Capacity single chamber: |
up to 100 ml |
|
Pressure range: |
0 - 8 bar |
|
Temperature range: |
from room temp. to 120 °C |
|
Max deviation from the set temperature |
≤ 0.5 °C |
|
Reproducibility of set temperature |
≤ ± 0.2 °C |
|
Interface: |
USB |
|
Connectivity |
Cloud via LAN or Wi-Fi |
|
Power |
900 W |
|
Power supply |
115 V / 60 Hz - 230 V / 50-60 Hz |
|
Weight: |
16.5 Kg (36.3 lb) |
|
Dimensions (WxHxD): |
365x190x485 mm (14.6x7.6x19.4 in) |
|
Overpressure |
Safety valve |
|
Out-range temperature |
Visual alarm |
|
Damaged probe |
Visual alarm |
Documents connexes
NOM DU DOCUMENT
DATE DE SORTIE
TÉLÉCHARGER
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais de matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimétrie
Électrochimie