This round bottom tube is designed for use in Beckman Coulter instruments and rotors. Ultra-Clear tubes are transparent, allowing for easy location of visibly banded or pelleted samples.
Compatible Ultracentrifuge Rotors
- Fixed Angle: Type 70 Ti, Type 50.2 Ti
- Swinging Bucket: SW 32 Ti, SW 28
Compatible High Performance Rotor
- Swinging Bucket: JS-24.38
Certified-free and sterile tubes are also available.
Silicone viscosity standard fluids are most commonly used to verify calibration of Brookfield lab viscometers anviscometers and rheometers and are less temperature sensitive than mineral oils.
General purpose silicone fluids are the most commonly used standard for verifying calibration of your Brookfield Viscometer/Rheometer.
Silicone Standards are for Newtonian fluids which are accurate to ±1% of viscosity value.
Silicone fluids provide excellent temperature stability and are less temperature sensitive than oil viscosity standards.
Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST).
The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument.
All fluids are supplied in ½ liter (1 pint) containers complete with a certificate of calibration.
FEATURES & BENEFITS
- Accuracy: ±1% of viscosity value
- Excellent temperature stability
- Recommended for use with Brookfield and most other rotational viscometers
- Most economical
- Special viscosity values and temperature calibrations available upon request
Silicone viscosity Standard fluids are most commonly used to verify the calibration of Brookfield lab viscometers/ rheometers and are less temperature sensitive than mineral oils.
General purpose silicone fluids are the most commonly used standard for verifying the calibration of your Brookfield Viscometer/Rheometer.
Silicone standards are for Newtonian fluids which are accurate to ±1% of viscosity value.
Silicone fluids provide excellent temperature stability and are less temperature-sensitive than oil viscosity standards.
Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST).
The selection of one or two fluids will normally provide sufficient measurement points to verify the calibration of your instrument.
All fluids are supplied in ½-liter (1 pint) containers complete with a certificate of calibration.
FEATURES & BENEFITS
- Accuracy: ±1% of viscosity value
- Excellent temperature stability
- Recommended for use with Brookfield and most other rotational viscometers
- Most economical
- Special viscosity values and temperature calibrations available upon request
Silicone viscosity standard fluids are most commonly used to verify calibration of Brookfield lab viscometers/ rheometers and are less temperature sensitive than mineral oils.
General purpose silicone fluids are the most commonly used standard for verifying the calibration of your Brookfield viscometer or rheometer.
Silicone Standards are Newtonian fluids which are accurate to ±1% of viscosity value.
Silicone fluids provide excellent temperature stability and are less temperature sensitive than oil viscosity standards.
Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST).
The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument.
All fluids are supplied in ½ liter (1 pint) containers complete with a certificate of calibration.
FEATURES & BENEFITS
- Accuracy: ±1% of viscosity value
- Excellent temperature stability
- Recommended for use with Brookfield and most other rotational viscometers
- Most economical
- Special viscosity values and temperature calibrations available upon request
Silicone viscosity standard fluids are most commonly used to verify calibration of Brookfield lab viscometers/ rheometers and are less temperature sensitive than mineral oils.
General purpose silicone fluids are the most commonly used standard for verifying calibration of your Brookfield Viscometer/Rheometer.
Silicone Standards are Newtonian fluids which are accurate to ±1% of viscosity value.
Silicone fluids provide excellent temperature stability and are less temperature sensitive than oil viscosity standards.
Brookfield Viscosity Standards are certified by methods traceable to the United States National Institute of Standards and Technology (NIST).
The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument.
All fluids are supplied in ½ liter (1 pint) containers complete with a certificate of calibration.
FEATURES & BENEFITS
- Accuracy: ±1% of viscosity value
- Excellent temperature stability
- Recommended for use with Brookfield and most other rotational viscometers
- Most economical
- Special viscosity values and temperature calibrations available upon request
Flexible G-96 WELL Gradient Block is used with Aeris™ Thermal Cycler and is interchangeable with four other blocs. An ideal way to adapt your device to your sample needs in capacity, quantity and labware format.
Accurate determination of a protein’s charge heterogeneity helps establish identity and stability. Capillary Isoelectric Focusing (cIEF) is a powerful technique that allows quantitative analysis of a protein’s isoelectric point (pI). In cIEF, a mixture of sample and ampholyte is introduced into a capillary and subjected to electrophoretic separation. In this process, a pH gradient through which analytes migrate to their respective pI is formed.
The PA 800 Plus Pharmaceutical Analysis System automates the advanced cIEF technology necessary to successfully achieve high precision and quantitative separations. The use of optimized universal methods and synthetic pI markers attains the highest levels of precision in pI calculation and direct isoform quantitation with on-line UV detection.
This kit provides reagent volumes for analysis of 100 samples and includes:
• eCap Neutral Capillary, 1 unit
• cIEF gel
• cIEF Peptide Marker Kit, 5 vials (pI 4.1, pI 5.5, pI 7.0, pI 9.5, pI 10.0), 240 µL each
• Sample Loading Solution (SLS), 6 mL
• CE Grade Water
NOTE: Additional reagents from other vendors are required for this application. Methods and necessary supplies can be referenced in the following AIBs, available for download at www.sciex.com:
• A-11634: Identification of System Parameters Critical for High-Performance cIEF
• A-12015: A Robust cIEF Method: Intermediate Precision for the pH 5-7 Range
• A-12026: High-Resolution cIEF of Therapeutic Monoclonal Antibodies: A Platform Method Covering pH 4-10
Calorific standard in powder or pellet form for standardizing all oxygen bomb calorimeters. Benzoic acid, 0.2 gram pellets, bottle of 1000 pellets.
The COULTER LATRON CP-X Control is supplied as a ready-to-use suspension of latex particles. These particles pass through the flow cell and produce
characteristic electrical signals that are measured as volume, conductivity and various angles of light scatter and light loss, for quality control of Coulter
Cellular Analysis Systems with VCSn technology.
MATERIALS PROVIDED:
• LATRON CP-X Control - 8 x 4 mL
• Table of EXPECTED RESULTS containing Assigned Values and EXPECTED RANGE
Cassette de capteurs pour la plateforme d'analyse biologique rapide et efficace Vi-CELL MetaFLEX.
La cassette de capteurs Vi-CELL MetaFLEX contient des capteurs pour les tests (à l'exception des tests d'oxymétrie et de bilirubine). Elle utilise une technologie de capteurs à couche épaisse et des capteurs miniaturisés pour permettre des mesures directes du glucose et du lactate à partir d'un échantillon de 100 μL (65 μL d'échantillon plus 35 μL de tare).
Le SC300 mesure le pH, la pO2, la pCO2, le glucose, le lactate, les électrolytes dans le milieu de culture cellulaire, ainsi que d'autres paramètres associés à l'analyse du sang total.
Le concentrateur rotatif sous vide RVC 2-18 CDplus, 230 V, 50/60 Hz (modèle de table) est une version standard avec chambre rotative en acier inoxydable, système d'entraînement magnétique, chambre rotative chauffée (240 W), couvercle avec hublot, verrouillage électrique et dispositif de sécurité. Système de commande convivial avec écran LCD.
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Enceintes de Protection
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie