Echo® Qualified 384-Well Polypropylene Microplate, Clear, Non-sterile
Echo® Qualified 384-Well Polypropylene (PP) Source Microplates ensure accurate and precise transfer with the Echo Liquid Handler. This microplate is highly resistant to solvents, including DMSO and buffers, making it ideal for compound and sample storage.
Les filtres HEPA (High-Efficiency Particulate Air) retiennent les particules inférieures à 0,3 µm. Les filtres VOC éliminent les composés organiques volatils — un large groupe de substances carbonées qui s'évaporent facilement à température ambiante — susceptibles de compromettre la culture embryonnaire. L'air d'un laboratoire de FIV peut contenir plus de VOC que l'air extérieur. Les VOC affectent nettement le taux de clivage, le développement embryonnaire et le taux de formation de blastocystes.
Filtre HEPA ESCO avec une efficacité de 99,99 % à 0,3 micron.
Filtre VOC ESCO pour éliminer les composés nocifs au développement embryonnaire.
À remplacer tous les 3 mois.
Accessoire pour :
-MRI-6A10
-MRI-TL
The Vi-CELL Focus Control is used during the autofocusing procedure when the system requires re-focusing. The focus control beads help the system refocus and offer a new recommended focus position. The cup of focus control is run similar to a sample run using the Vi-CELL carousel sample delivery method.
For use in the Vi-CELL BLU and Vi-CELL XR cell viability analyzers.
Four à vide VO29, avec TwinDISPLAY, 29 l, plage de température de fonctionnement minimale 5 °C au-dessus de la température ambiante jusqu'à +200 °C, plage de température réglable 20 °C - 200 °C. Régulation électronique numérique de la pression de 5 à 1100 mbar. Avec régulation de la pompe, procédures de rinçage optimisées pour les membranes de la pompe et sortie de signal pour la pompe MARCHE/ARRÊT, étagère thermique avec 1 raccordement pour étagères thermiques à l'arrière, porte en verre de sécurité avec verre pare-balles à l'intérieur et écran anti-éclaboussures externe. Équipé d'une porte en acier inoxydable, d'un clapet d'air réglable électroniquement de 0 à 100 % par paliers de 10 %, d'une interface Ethernet pour la lecture du journal des protocoles, le téléchargement de programmes et la journalisation en ligne. Port USB sur ControlCOCKPIT pour l'utilisation d'une clé USB, protection multiple contre la surchauffe, enregistreur de données interne avec une capacité de stockage d'au moins 10 ans, fonction d'étalonnage. Certificat d'étalonnage pour un fonctionnement à +160 °C et une pression de 20 mbar. Extérieur en acier inoxydable structuré : 550 x 607 x 400 mm ; intérieur en acier inoxydable : 385 x 305 x 250 mm. Tension : 230 V, 50/60 Hz ; puissance électrique max. : env. 420 W.
La hotte Captair Smart 321 d'Erlab est une hotte à filtration sans raccordement qui protège l'utilisateur des vapeurs dangereuses produites par ses échantillons. Elle est silencieuse, facile à utiliser et entièrement personnalisable en fonction des besoins et des applications de votre laboratoire.
Caractéristiques:
- Ouverture de type oblong
- Réduisez les coûts d'installation, d'entretien et de fonctionnement grâce à une hotte sans raccordement
- Grâce à la technologie SMART inégalée d'Erlab, vous pouvez travailler en toute confiance, sachant que vous êtes entièrement protégé contre les fumées et particules dangereuses produites par vos applications de laboratoire
- Une communication simple par des impulsions sonores et lumineuses claires indique diverses informations, notamment les défauts, la durée de fonctionnement, la vitesse de l'air, la saturation du filtre, les réglages de ventilation, les pannes de ventilateur, etc.
- Dimensions globales (L x P) 780 x 620 mm. La hauteur dépend de la configuration du filtre et peut être comprise entre 1110 et 1285 mm.
- Acier électro-galvanisé résistant à la corrosion, recouvert d'un polymère anti-acide
- L'application eGuard est disponible pour la surveillance à distance de la hotte, la modification des paramètres et l'envoi immédiat d'alertes de sécurité sur vos appareils (téléphone mobile, tablette et PC)
- Une colonne de filtration pouvant être configurée pour traiter les liquides, les poudres ou les deux.
- Surveillance continue de la vitesse de l'air.
- 65W
Options:
- Trois options différentes pour la surface de travail avec bac de récupération intégré (Trespa/résine phénolique, acier inoxydable 304L ou verre trempé)
- Peut être fourni avec un plan de travail fixe ou mobile, ou vous pouvez utiliser votre propre plan de travail
- Le capteur de détection Molecode est disponible en trois types (acide, solvants et formaldéhyde)
- En nous indiquant les produits chimiques que vous manipulez, nous pouvons calculer le type de charbon actif ou de filtres HEPA dont vous avez besoin et mettre en place un programme de rotation des filtres afin de garantir une protection totale pendant de nombreuses années
- Filtre de sécurité en cas de saturation du filtre principal
- Disponible avec plusieurs options de robinets (azote, eau chaude, eau froide, vide, gaz naturel, air comprimé, eau distillée, eau non ionisée, méthane, etc.)
- Panneau arrière transparent
- Prise électrique interne 240 V
- Écoulement des déchets
- Évier (30 x 15 cm), emplacement à indiquer par le client
- Contrat de garantie et de service exclusif Analis disponible, comprenant des visites annuelles et le remplacement des filtres
Alimentation électrique :
- 230 V standard
Normes de sécurité
- AFNOR NF X 15-211:2009 : France - BS 7989 : Angleterre, DIN 12 927 : Allemagne - EN 1822:1998 (filtres HEPA H14 et ULPA U17) - Marquage CE
Kit Component of P/N 390953 and P/N A10663 (IgG Purity/Heterogeneity Kit.)
For use as an experimental control when separating reduced or non-reduced IgG, with a designated quantity of non-glycosylated heavy chain to test both the resolution and quantitation suitability of the assay prior to running unknowns.
Includes IgG Control Standard 1-pack and all chemistries.
The IgG Purity/Heterogeneity Assay has been developed for researchers employed in industrial biotechnology who are developing and manufacturing IgG reagents for research, diagnostic and therapeutic use.
This assay has been specified for use on the PA 800 Plus to assess the purity and heterogeneity of IgG reagents in both a reduced and non-reduced state. The methodology involves heat-denaturing a specified concentration of IgG (both reduced and non-reduced) in the presence of SDS, and separating these proteins by size using high-resolution capillary gel electrophoresis technology. This assay will detect impurities as low as 0.1% and includes an IgG control with a designated quantity of non-glycosylated heavy chain to test both the resolution and quantitation suitability of the assay prior to running unknowns
Assay chemistry includes:
• Separation Capillary, 57 cm x 50 µm ID bare fused-silica, (2)
• SDS Gel Separation Buffer (proprietary formulation), 140 mL
• SDS Sample Buffer, 100 mM Tris-HCl, pH 9.0/1% SDS, 50 mL
• IgG Control Standard, 1 mg/mL in SDS sample buffer , 1 mL
• Internal Standard, 10 kDa protein, 5 mg/mL, 0.4 mL
• Acidic Wash Solution, 0.1 N HCl, 100 mL
• Basic Wash Solution, 0.1 N NaOH, 100 mL
• IgG Purity and Heterogeneity Analysis Guide, (1)
Le kit d'analyse SDS-Gel MW est conçu pour la séparation et la quantification des complexes protéiques SDS à l'aide d'une matrice de gel remplaçable. Le gel est composé de manière à offrir une plage de tamisage protéique effective d'environ 10 à 225 kDa. Dans cette plage de taille, le logarithme de la masse moléculaire de la protéine est linéaire avec la mobilité électrophorétique réciproque. Ainsi, le poids moléculaire d'une protéine inconnue peut être estimé à l'aide d'une courbe standard de tailles de protéines connues. Cette chimie peut également être utilisée pour quantifier efficacement la quantité de protéines et déterminer la pureté d'un produit protéique.
Contenu
• Capillaire de séparation, 57 cm x 50 µm ID, silice fondue non revêtue, (2)
• Tampon de séparation sur gel SDS, 140 mL
• Tampon d'échantillonnage SDS, 100 mM Tris-HCl, pH 9,0/1 % SDS, 50 mL
• Étalon de taille des protéines SDS (10 à 225 kDa), 16 mg/mL, 100 µL
• Étalon interne, protéine de 10 kDa, 5 mg/mL, 0,4 mL
• Solution de lavage acide, HCl 0,1 N, 100 mL
• Solution de lavage basique, NaOH 0,1 N, 100 mL
• Guide d'analyse MW par gel SDS (1)
Le kit eCAP dsDNA 1000 est conçu pour la reconnaissance de profils de fragments d'ADN, la quantification de fragments PCR et la détermination de la taille moléculaire sur les systèmes SCIEX CE. Cette chimie utilise du polyacrylamide linéaire en solution pour former un gel de séparation. Le capillaire neutre fourni avec ce kit est recouvert d'une couche stable de polyacrylamide physiquement liée qui élimine le courant électro-osmotique (EOF) et supprime les interactions entre l'échantillon et la paroi du capillaire. Ce processus chimique utilise un tampon Tris-Borate EDTA standard, auquel peuvent être ajoutés des colorants intercalants tels que le bromure d'éthidium ou notre propre EnhanCE™ afin d'améliorer la résolution et d'augmenter la sensibilité. Ce kit est idéal pour l'analyse de fragments d'ADN double brin de 72 à 1 000 paires de bases et pour l'analyse de produits PCR, qui peuvent être analysés directement sans nettoyage de l'échantillon. Les applications de ce kit comprennent l'analyse de l'expression génique (PCR compétitive) et les expériences de génotypage. Le système est compatible avec la détection UV et LIF, mais la détection LIF est recommandée pour la plupart des applications. Pour les applications LIF, nous recommandons l'utilisation du colorant intercalant EnhanCE. Ce kit n'est pas compatible avec la détection PDA.
Le kit contient des réactifs pour l'analyse de 100 échantillons et comprend :
> > 100 µm I.D. 65 cm, 2 capillaires neutres (ADN),
> des flacons contenant un gel de polyacrylamide remplaçable,
> un mélange de test composé d'ADN digéré par la restriction HaeIII 174 avec 11 fragments de 72 bp à 1353 bp,
> ainsi que des instructions et des méthodes pour la configuration et l'analyse du système.
LIF Test Mix, Sodium Fluorescein (20 mL). Test mix for testing the Laser-Induced Fluorescence (LIF) detector and determining the calibration correction factor (CCF) for the system.
Molecular Weight standards (10 to 225 KDa), 16mg/mL (100 µL) for use with the SDS-MW Kit (Part Number 390953) to provide a sizing ladder to reference proteins of interest against.
OptiMATE Iodixanol Solution (BEC-D01358) from Beckman Coulter is the ideal choice for laboratory scientists in Belgium and Luxembourg performing ultracentrifugation. This high-purity iodixanol solution is specifically designed for density gradient centrifugation, making it perfect for viral, organelle, extracellular vesicle (EV), and protein separations. With an 80% concentration, it allows for increased sample volume per tube and reduces bottle-related waste, enhancing your lab’s efficiency.
Key Features:
- High Purity: Ensures reliable and reproducible results.
- Optimal Concentration: 80% w/v for effective separations.
- Versatile Applications: Suitable for viral, organelle, EV, and protein separations.
- Reduced Waste: Minimize bottle-related waste with concentrated solution.
- Sterile and Safe: Autoclaved for sterility, with low endotoxin levels.
Agitateurs et shakers
Agrégation plaquettaire
Analyse cellulaire
Analyse de l'humidité
Analyse urinaire
Caractérisation des particules
Centrifugation
Chauffage et refroidissement
Chimie analytique
Chimie clinique
Chromatographie flash & préparative
Contrôle environnemental
Contrôles de qualité cliniques
Couleur-Apparence et tests physiques
Culture cellulaire et fermentation
Cytométrie en flux
Désinfection
Electrophorèse capillaire
Essais et caractérisation des matériaux
Fécondation in vitro (FIV)
Hottes de Protection
Hématologie
Imagerie biologique
Immuno-hématologie
Immunoassay
Lyophilisation
Microbiologie (clinique)
Microscopie
Mobilier de laboratoire et études de conception
Métrologie
Nephelometry (Néphélométrie)
Nettoyage Lavage
POCT
Pesage
Pipetage de liquides (manuel)
Pompes
Préparation d'échantillon
Purification de l'eau
Rhéomètres
Robot de pipetage
Solutions d'automatisation clinique (TLA)
Solutions informatiques cliniques
Spectromètres de masse
Stockage
Stérilisation
Synthèse
Tests sur tablettes
Texturomètres
Toxicologie
Tri cellulaire par Cytométrie en flux
Viscosimètres
Électrochimie