56gr tube Spinkote Lubricant for metal threads in Beckman Coulter rotors.
The lubricant is part of the recommended maintenance procedures for certain types of equipment. Following these procedures can help ensure the equipment operates correctly and has a long service life.
This can help reduce friction, prevent corrosion, and extend the life of the threads.
Contains cartridge body, 100 x 800 µm aperture, 100 x 200 µm aperture, tubing kit, nuts, ferrules, and O-rings. This cartridge body comes with 60 cm coolant tubing installed and also includes 30, 40, and 50 cm tubing.
This round bottom tube is designed for use in Beckman Coulter instruments and rotors. Ultra-Clear tubes are transparent, allowing for easy location of visibly banded or pelleted samples.
Compatible Ultracentrifuge Rotors
• Fixed Angle: Type 70 Ti, Type 50.2 Ti
• Swinging Bucket: SW 32 Ti, SW 28
Compatible High Performance Rotor
• Swinging Bucket: JS-24.38
Certified Free*
• Exhibits no detectable DNA, DNase, RNase, PCR inhibitors, or endotoxins
• Prevents sample degradation and contamination
• Improve QC data quality
Sterile
• Sterilized via ethylene oxide
• Pre-sterilized ready-to-use for improved workflow efficiency
• Eliminate need for developing sterilization protocol
• Packaged in workflow based quantities
• Sterilized and packaged compliant with ISO 11135:2014, and ISO 11607:2006
Recommended Applications
• Microbiology
• Gene therapy
• Biotherapeutics
• Molecular biology
• Cell culture
• Plant and animal derived products
• Algae
Certified Free and Beckman standard tubes are also available.
*Based on sample results below detectable limits.
Certificates available here.
This round bottom tube is designed for use in Beckman Coulter instruments and rotors. Quick-Seal tubes provides a secondary BioSafe containment. It also allows you to seal with a simple, hand-held sealing tool without plugs or O-rings. Quick-Seal tube spacer required.
Compatible Ultracentrifuge Rotors
• Ultracentrifuge: Type 45 Ti
Compatible High Performance Rotor
• High performance: JA-18
Certified Free*
• Exhibits no detectable DNA, DNase, RNase, PCR inhibitors, or endotoxins
• Prevents sample degradation and contamination
• Improve QC data quality
Sterile
• Sterilized via ethylene oxide
• Pre-sterilized ready-to-use for improved workflow efficiency
• Eliminate need for developing sterilization protocol
• Packaged in workflow based quantities
• Sterilized and packaged compliant with ISO 11135:2014, and ISO 11607:2006
Recommended Applications
• Microbiology
• Gene therapy
• Biotherapeutics
• Molecular biology
• Cell culture
• Plant and animal derived products
• Algae
Certified Free and Beckman standard tubes also available.
*Based on sample results below detectable limits.
Certificates available here.
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Vacuümoven VO29, met TwinDISPLAY, 29 l, bereik werktemperatuur minimaal 5 °C boven omgevingstemperatuur tot +200 °C, bereik instelinsteltemperatuur 20 °C - 200 °C. Ddigitale elektronische drukregeling van 5 - 1100 mbar. Met pompregeling, geoptimaliseerde spoelprocedures voor de pompmembranen en signaaluitgang voor pomp AAN/UIT, thermoshelf met 1 aansluiting voor thermoshelves aan de achterzijde, veiligheidsglasdeur met kogelvrij glas aan de binnenzijde en extern spatscherm. Voorzien van roestvrijstalen deur, elektronisch instelbare luchtklep van 0 tot 100 % in stappen van 10 %, Ethernet-interface voor het uitlezen van het protocol-logboek, het uploaden van programma's en voor online logging. USB-poort op ControlCOCKPIT voor gebruik van USB-stick, meervoudige overtemperatuurbeveiliging, interne datalogger met een opslagcapaciteit van minimaal 10 jaar, ijkingsfunctie. IJkcertificaat voor werking bij +160 °C en 20 mbar druk. Buitenkant van gestructureerd roestvrij staal: 550 x 607 x 400 mm; binnenkant van roestvrij staal: 385 x 305 x 250 mm. Spanning: 230 V, 50/60 Hz; max. elektrisch vermogen: ca. 420 W
For use with the Vi-CELL XR Cell Viability Analyzer.
The concentration control consists of a mixture of latex beads at 1x106 beads/mL concentration.
It is recommended to run daily to verify that the Vi-CELL is counting properly.
Your legacy Vi-CELL XR cell counter and viability analyzer is now replaced by the Vi-Cell BLU
Deze reagentia zijn bedoeld voor gebruik in de Vi-CELL™ XR- Cell Viability Analyzer als het instrument is geïntegreerd in een geautomatiseerd monsternameapparaat. Let op: dit pakket bevat geen monstervials.
Vertrouwen is een essentieel aspect van elke relatie. Daarom willen we u graag laten zien welke voordelen en zekerheid u krijgt wanneer u Vi-CELL™-reagentia van Beckman Coulter Life Sciences aanschaft. De Vi-CELL™-reagentia bieden:
-Gevalideerde reagentia met geschikte reinigings- en desinfectiemiddelen
-Analysecertificaat voor elke batch
-Garantie op basis van servicecontract
Breng uw proeven niet in gevaar, gebruik altijd reagentia van Beckman Coulter, een bedrijf dat u kent en vertrouwt. Het gebruik van Vi-CELL™-reagentia die niet van Beckman Coulter zijn, kan leiden tot frequente fouten in de lichtintensiteit en verstopping van de vloeistofleidingen, waardoor onnodige servicebezoeken nodig zijn. Onze interne tests hebben aangetoond dat het gebruik van niet-Beckman Coulter-reagentia met de Vi-CELL™ leidt tot een geleidelijke verdonkering van de stroomcellen, waardoor de achtergrondintensiteit daalt en een foutmelding over de lichtintensiteit wordt gegenereerd. Dit probleem wordt verholpen door een ontsmettingscyclus uit te voeren en vervolgens het Beckman Coulter Vi-CELL™ Reagent Pak op het systeem te gebruiken.
Heeft u al nagedacht over een upgrade naar de volgende Vi-CELL-generatie? Bekijk de nieuwe Vi-CELL BLU
https://analis.odoo.com/categ/cell-counters-viability-analyzers
Siliconen-viscositeitsstandaardvloeistoffen worden vaak gebruikt om de kalibratie van Brookfield-viscosimeters en -reometers te verifiëren en zijn minder temperatuurgevoelig dan minerale oliën.
Siliconenvloeistoffen voor algemeen gebruik zijn de meest gebruikte standaard om de kalibratie van uw Brookfield-viscosimeter of -reometer te verifiëren.
Siliconenstandaarden zijn newtoniaanse vloeistoffen, nauwkeurig tot ±1% van de viscositeitswaarde.
Siliconenvloeistoffen bieden uitstekende temperatuurstabiliteit en zijn minder temperatuurgevoelig dan olie-standaarden.
Brookfield-viscositeitsstandaarden zijn gecertificeerd via methoden herleidbaar tot het National Institute of Standards and Technology (NIST) van de VS.
Eén of twee vloeistoffen leveren doorgaans genoeg meetpunten om de kalibratie van uw instrument te verifiëren.
Alle vloeistoffen worden geleverd in ½-litercontainers (1 pint) met een kalibratiecertificaat.
KENMERKEN EN VOORDELEN
- Nauwkeurigheid: ±1% van de viscositeitswaarde
- Uitstekende temperatuurstabiliteit
- Aanbevolen voor Brookfield- en de meeste andere rotatieviscosimeters
- Zeer voordelig
- Speciale viscositeitswaarden en temperatuurkalibraties op aanvraag
Separation Buffer for performing capillary Isoelectric Focusing.
(100 mL).
Gel used in the cIEF application for experimentally determining a molecule's isoelectric point (pI) and the various charge variants of the molecule.
pI Marker Kit features synthetic peptides for high resolution and quantitative reproducibility in calculating protein pI. The combination of the advanced cIEF methods, the synthetic pI markers, and the PA 800 Plus system results in cIEF separations with the highest level of precision for pI determination and isoform quantitation of your sample.
This kit includes:
• Five vials containing 240 µL each of peptides with the following pI values: pI 4.1, pI 5.5, pI 7.0, pI 9.5, pI 10.0.
This volume enables 100 cIEF runs.
Beschermingskasten
Biologische beeldvorming
Bloedplaatjesaggregatie
Capillaire elektroforese
Celculturen en fermentatie
Cellulaire analyse
Centrifugatie
Chromatografie (flash & prep)
DNA / RNA (nucleïnezuren)
Deeltjeskarakterisatie
Desinfectie
Elektrochemie
Flowcytometrie
Flowcytometrie celsorting
Geautomatiseerde Liquid Handling
Hematologie
Immuno-hematologie
Immunodosage
In-vitrofertilisatie (IVF)
Kleur-Appearance en fysische testen
Klinische IT-oplossingen
Klinische automatisering (TLA)
Klinische chemie
Klinische kwaliteitscontroles
Laboratoriummeubilair & ontwerpstudies
Massaspectrometers
Materiaaltesten en -karakterisering
Metrologie
Microbiologie (Klinische)
Microscopie
Monstersvoorbereiding
Nefelometrie
Omgevingscontrole
Opslag
POCT
Pipetteren van vloeistoffen (handmatig)
Pompen
Reinigen
Reometers
Shakers and stirrers
Sterilisatie
Synthese
Tablet testing
Texturometers
Toxicologie
Urineanalyse
Verwarmen & koelen
Viscometers
Vochtanalyse
Vriesdrogen
Waterzuivering
Wegen