56gr tube Spinkote Lubricant for metal threads in Beckman Coulter rotors.
The lubricant is part of the recommended maintenance procedures for certain types of equipment. Following these procedures can help ensure the equipment operates correctly and has a long service life.
This can help reduce friction, prevent corrosion, and extend the life of the threads.
Contains cartridge body, 100 x 800 µm aperture, 100 x 200 µm aperture, tubing kit, nuts, ferrules, and O-rings. This cartridge body comes with 60 cm coolant tubing installed and also includes 30, 40, and 50 cm tubing.
This round bottom tube is designed for use in Beckman Coulter instruments and rotors. Ultra-Clear tubes are transparent, allowing for easy location of visibly banded or pelleted samples.
Compatible Ultracentrifuge Rotors
• Fixed Angle: Type 70 Ti, Type 50.2 Ti
• Swinging Bucket: SW 32 Ti, SW 28
Compatible High Performance Rotor
• Swinging Bucket: JS-24.38
Certified Free*
• Exhibits no detectable DNA, DNase, RNase, PCR inhibitors, or endotoxins
• Prevents sample degradation and contamination
• Improve QC data quality
Sterile
• Sterilized via ethylene oxide
• Pre-sterilized ready-to-use for improved workflow efficiency
• Eliminate need for developing sterilization protocol
• Packaged in workflow based quantities
• Sterilized and packaged compliant with ISO 11135:2014, and ISO 11607:2006
Recommended Applications
• Microbiology
• Gene therapy
• Biotherapeutics
• Molecular biology
• Cell culture
• Plant and animal derived products
• Algae
Certified Free and Beckman standard tubes are also available.
*Based on sample results below detectable limits.
Certificates available here.
This round bottom tube is designed for use in Beckman Coulter instruments and rotors. Quick-Seal tubes provides a secondary BioSafe containment. It also allows you to seal with a simple, hand-held sealing tool without plugs or O-rings. Quick-Seal tube spacer required.
Compatible Ultracentrifuge Rotors
• Ultracentrifuge: Type 45 Ti
Compatible High Performance Rotor
• High performance: JA-18
Certified Free*
• Exhibits no detectable DNA, DNase, RNase, PCR inhibitors, or endotoxins
• Prevents sample degradation and contamination
• Improve QC data quality
Sterile
• Sterilized via ethylene oxide
• Pre-sterilized ready-to-use for improved workflow efficiency
• Eliminate need for developing sterilization protocol
• Packaged in workflow based quantities
• Sterilized and packaged compliant with ISO 11135:2014, and ISO 11607:2006
Recommended Applications
• Microbiology
• Gene therapy
• Biotherapeutics
• Molecular biology
• Cell culture
• Plant and animal derived products
• Algae
Certified Free and Beckman standard tubes also available.
*Based on sample results below detectable limits.
Certificates available here.
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Vacuum oven VO29, with TwinDISPLAY, 29 l, working-temperature range at least 5 °C above ambient temperature to +200 °C, setting temperature range 20 °C - 200 °C; digital electronic pressure control from 5 - 1100 mbar, with pump control, optimised rinsing procedures for the pump membranes as well as signal output for pump ON/OFF, with thermoshelf with 1 connector for thermoshelves in the back, safety glass door with inner bullet-proof glass and external anti-spinter screen; stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, uploading programmes and for online logging, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C and 20 mbar pressure; textured stainless steel exterior: 550 x 607 x 400 mm; stainless steel interior: 385 x 305 x 250 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 420 W
For use with the Vi-CELL XR Cell Viability Analyzer.
The concentration control consists of a mixture of latex beads at 1x106 beads/mL concentration.
It is recommended to run daily to verify that the Vi-CELL is counting properly.
Your legacy Vi-CELL XR cell counter and viability analyzer is now replaced by the Vi-Cell BLU
These reagents are for use in the Vi-CELL™ XR Cell Viability Analyzer when the instrument is integrated to an automated sampling device. Please note that this package does not include sample vials.
Trust is an integral component of any relationship. So, let us illustrate the value and peace of mind that you will receive when you purchase Vi-CELL™ Reagents from Beckman Coulter Life Sciences. Vi-CELL™ Reagents offer:
-Validated reagent with appropriate cleaning and disinfectant solutions
-Certificate of Analysis for each lot
-Service contract guarantee
Don’t put your experiments at risk, always use Beckman Coulter reagents, a company you know and trust. Using Non-Beckman Coulter Vi-CELL™ reagents may result in frequent light intensity errors and clogging of the fluid lines, creating unnecessary Service visits. Our in-house testing has demonstrated that using Non-Beckman Coulter reagents with the Vi-CELL™ leads to gradual darkening of the flow cells which lowers the background intensity and generates a light intensity error message. This issue is corrected if a decontamination cycle is performed and the Beckman Coulter Vi-CELL™ Reagent Pak is subsequently used on the system.
Did you yet think about an upgrade to the next Vi-CELL generation ? Look at the new Vi-CELL BLU
https://analis.odoo.com/categ/cell-counters-viability-analyzers
Separation Buffer for performing capillary Isoelectric Focusing.
(100 mL).
Gel used in the cIEF application for experimentally determining a molecule's isoelectric point (pI) and the various charge variants of the molecule.
pI Marker Kit features synthetic peptides for high resolution and quantitative reproducibility in calculating protein pI. The combination of the advanced cIEF methods, the synthetic pI markers, and the PA 800 Plus system results in cIEF separations with the highest level of precision for pI determination and isoform quantitation of your sample.
This kit includes:
• Five vials containing 240 µL each of peptides with the following pI values: pI 4.1, pI 5.5, pI 7.0, pI 9.5, pI 10.0.
This volume enables 100 cIEF runs.
The eCAP dsDNA 1000 Kit is designed for DNA fragment pattern recognition, quantitation of PCR fragments, and molecular sizing on SCIEX CE Systems.
This chemistry utilizes linear polyacrylamide in solution to form a sieving gel. A neutral capillary provided with this kit has a stable, physically bonded polyacrylamide coating that eliminates electroosmotic flow (EOF) and suppresses interactions of the sample with the capillary wall. This chemistry utilizes a standard Tris-Borate EDTA buffer and allows the addition of intercalating dyes like ethidium bromide or our proprietary EnhanCE™ to improve resolution and increase sensitivity.
This kit is ideal for the analysis of double-stranded DNA fragments from 72 to 1000 base pairs as well as for the analysis of PCR products, which can be analyzed directly with no sample clean-up. Applications of this kit include gene expression analysis (competitive PCR), and genotyping experiments.
The system is compatible with both UV and LIF detection, but LIF is recommended for most applications. For LIF applications, we recommend the use of the intercalating dye EnhanCE. This kit is not compatible with PDA detection.
Kit provides reagent volumes for analysis of 100 samples and includes:
> 100 µm I.D. 65 cm, 2 units neutral capillaries (DNA),
> vials of replaceable polyacrylamide gel,
> test mix consisting of HaeIII restriction digest 174 DNA containing 11 fragments from 72 bp to 1,353 bp,
> and instructions and methods for system set-up and analysis.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing