- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Thermal analysis
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Heating & cooling Incubation Incubators
- Cooling Incubator KB 65
HOME / APPLICATIONS & TECHNIQUES /
Cooling Incubator KB 65
Reference: BIN-9020-0471
https://www.analis.com/shop/bin-9020-0471-cooling-incubator-kb-65-127898 https://www.analis.com/web/image/product.template/127898/image_1920?unique=1b10c30The BINDER KB 65 is a high-performance cooling incubator for micro-organisms, with a volume of 63 liters and a temperature range of 0 to 70 °C. KB units incubate with exceptional precision, even when fully loaded. They also include a hot air decontamination routine and are easy to program for weekend operation. The new KB unit uses up to 40% less energy than the previous model.
What is a cooling incubator?
A cooling incubator can both heat and cool, so samples can be incubated or stored above as well as below ambient temperature. Cooling incubators are standard laboratory equipment in microbiology, where stable incubation conditions are essential and exact, constant temperatures must be guaranteed.
How does the KB 65 keep the temperature constant?
- Airflow : a double-sided horizontal airflow keeps the temperature constant across all shelves. A fan draws air into the double rear wall, where it is re-conditioned to the set temperature. The air then flows through the perforated side walls back into the usable space.
- Preheating : the proven APT.line™ preheating chamber technology from BINDER supports this homogeneity.
- Observation : a glass inner door lets you see the samples without disturbing the interior atmosphere. Safety glass inner doors with a metal oxide coating and door heating prevent condensation.
Key advantages
- Double-sided horizontal airflow for a constant temperature across all shelves
- Glass inner door providing a view of the samples without affecting the interior atmosphere
- APT.line™ preheating chamber technology, proven in BINDER units
- Climate-neutral R-600a refrigerant for cooling
- Interior made entirely of stainless steel
- Internal data logger with readings that can be exported in an open format via USB
- Safety glass inner doors with metal oxide coating and door heating to prevent condensation
Technical specifications
- Temperature range : 0–70 °C
- Volume : 63 liters
- Internal dimensions (W × H × D) : 406 × 400 × 386 mm
- Load per shelf : 25 kg
Suitable for
Cooling incubators are used in many fields of microbiology:
- Life sciences and medicine : fundamental and medical research
- Pharmaceutical research : drug research (mostly cell culture, but also microbiology)
- Food industry : sterility tests and colony counting (sterility, bioburden)
- Recognized testing bodies : drinking water analysis
- Pharmaceutical production : environmental monitoring and water analysis
- Energy storage : battery research and development, using cooling incubators as climate chambers without humidity control
- Pharmaceutical and cosmetics industry : swing tests of ointments and emulsions (freeze-thaw stability tests)
Request a demonstration or quote
Ask Analis' local Benelux experts for more information, a demonstration, or a personalized quote.
Technical information
Category | Specification |
Temperature range | 0–70 °C |
Internal dimensions (W x H x D) | 406 x 400 x 386 |
Volume | 63 liters |
Load per shelf | 25 kg |
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Thermal analysis
Toxicology
Urine analysis
Viscometers
Water purification
Weighing