- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Thermal analysis
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Material testing & characterization Surface & nanolayer characterization
- MP-SPR NAVI 210A VASA
HOME / APPLICATIONS & TECHNIQUES /
MP-SPR NAVI 210A VASA
Reference: BION-SPR210A-VASA
https://www.analis.com/shop/bion-spr210a-vasa-mp-spr-navi-210a-vasa-147790 https://www.analis.com/web/image/product.template/147790/image_1920?unique=ad3a0d8The BioNavis MP-SPR Navi 210A VASA uses Multi-Parametric Surface Plasmon Resonance (MP-SPR) to record the complete SPR curve in a single measurement, in both gas and liquid. It registers the adhesion of molecules to each other or to surfaces, including fouling and antifouling, quickly and label-free, for material science and life science.
The 210A VASA adds automated liquid handling for up to 6 samples without user intervention, which makes it the automation-focused model in the MP-SPR Navi range.
What does the 210A VASA measure?
MP-SPR records the full SPR curve, so beyond standard SPR it delivers both interaction and layer data:
- Molecular interactions: kinetics (kon, koff), affinity (KD), concentration, adsorption/desorption, adhesion
- PureKinetics™: small molecules, lipids and biomaterials without bulk effect (the typical DMSO artifact)
- Electrochemistry: E, I, ω
- Layer properties: refractive index (n), thickness (d), extinction coefficient (k), density (ρ), surface coverage (Γ), swelling (Δd), optical dispersion (n(λ))
Its application range extends from small molecules to nanoparticles and even living cells, and measurements run in complex media such as serum.
What sets the 210A VASA apart?
The VASA is built for automated, higher-throughput MP-SPR: automated liquid handling for up to 6 samples, a software switch between serial and parallel injections, and optional loop injections to minimise sample consumption. 4 simultaneous measurements in 2 liquid channels (two independent wavelengths at the same spot) detect thickness, refractive index or conformation changes at once, and a wide 40°–78° angle range covers everything from small organic molecules to large proteins, cells and metal nanoparticles.
Key advantages
- Automated liquid handling for up to 6 different samples without user intervention
- Software switch for serial and parallel injections
- Optional loop injections to minimize sample consumption
- 4 simultaneous measurements in 2 liquid channels through two independent wavelength measurements at the same spot, enabling detection of thickness, refractive index or conformation changes
- Wide angle range of 40°–78° to measure small organic molecules, large proteins and cells, as well as metal nanoparticles
- Gas and liquid in one scan with bulk effect separation using PureKinetics™
- Precise injection pumps and integrated degasser for ideal buffer flow conditions
- Easy sensor exchange thanks to optical RI matching elastomer, so sensors can be analyzed further with methods such as AFM or microscopy
- Open design with easy access to the removable flow cell, tubing, pump and injection valve
Suitable for
- Molecular interaction analysis (kinetics, affinity, concentration)
- Adhesion, fouling and antifouling studies
- Layer characterization (thickness, refractive index, conformation)
- Material science and life science, from small molecules to living cells
Request a demonstration or quote
Download the brochure below for full specifications. Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Technical information
Category | Specification |
Number of measurements | 1 to 6 samples (automatic) |
Number of channels | 2 |
Layer thicknesses | 3 [Dampstroom] to several µm |
Sample volume | 300 µl |
Injection volume | 80 µl to 500 µl |
Minimum injection volume | 50 µl |
Lasers | 2 (670nm and 785nm) |
Software
The MP-SPR Navi™ instruments come with user-friendly software packages for data acquisition and analysis: MP-SPR Navi™ Control and MP-SPR Navi™ DataViewer. Both are supplied with all instruments and are available for an unlimited number of computers. The 210A is supplied with MP-SPR Navi™ LayerSolver to determine thickness and RI from multi-wavelength measurements. For advanced analysis, TraceDrawer™ is available for molecular interactions (optional, for affinity and kinetic constants) and LayerSolver™ for true layer characterization.
The BioNavis MP-SPR Family
The family ranges from the MP-SPR Navi™ 200 OTSO to the MP-SPR Navi™ 420A ILVES. The instruments are designed and manufactured in Finland. In honor of their Finnish roots, BioNavis named its instruments after Finnish wildlife: OTSO and KONTIO (bears), VASA (a reindeer), KAURIS (an ibex), NAALI (an arctic fox) and ILVES (a lynx).
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Thermal analysis
Toxicology
Urine analysis
Viscometers
Water purification
Weighing