- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Protection cabinets Biosafety cabinets
- AC2-4S8 Airstream® ClassII, Biological Safety Cabinet (S-Series), 1.2m
HOME / APPLICATIONS & TECHNIQUES /
AC2-4S8 Airstream® ClassII, Biological Safety Cabinet (S-Series), 1.2m
Reference: ESC-2010711
https://www.analis.com/shop/esc-2010711-ac2-4s8-airstream-r-classii-biological-safety-cabinet-s-series-1-2m-3533 https://www.analis.com/web/image/product.template/3533/image_1920?unique=9c80963The Esco Airstream® Gen 3 Class II Biological Safety Cabinet (AC2) is an effective solution in providing operator, product and environmental protection. It also features stable and self-compensating airflow, despite building voltage fluctuations & filter loading. Certified to EN 12469, Esco Airstream® Class II Biological Safety Cabinet also has antimicrobial coating on all its external and internal painted surfaces for improved safety.
The AC2- S series Class II Biosafety cabinet features a one-piece stainless steel with coved corners for cleanability. The side capture zones and negative pressure side walls optimize containment.
Technical information
| Section | Details |
|---|---|
| A. General Construction | |
| External Dimensions | - Without Base stand: 1340 x 810 x 1400 mm (52.8” x 32.0” x 55.1”) - With Optional Base stand 711 mm (28”): 1340 x 810 x 2111 mm (52.8” x 32.0” x 83.1”) |
| Internal Work Area Dimensions | - 1220 x 580 x 660 mm (48.0” x 22.8” x 26.0”) - Area: 0.56 m² (6.1 ft²) |
| Working Opening | 190 mm (7.5”) |
| Material | - Main body: 1.2 mm (0.05”) 18-gauge electro-galvanized steel with white oven-baked epoxy-polyester anti-microbial powder coated finish - Work Zone: Abrasion and corrosion-resistant 304 grade, 1.5 mm 16-gauge stainless steel with 4B finish - Side walls: 1.5 mm (0.06”) 16 gauge stainless steel, type 304, with 4B finish - ISOCIDE™ Antimicrobial Powder coating |
| Weight | 230 kg (507 lbs) (Excluding optional stand) |
| B. Blower and Filtration | |
| Blower | Equipped with one Direct Current Electronically Commutated Motor (DC ECM) - Low heat and low energy consumption offering 70% more energy savings |
| Auto-compensating feature | Adjusts blower speed to maintain optimum airflow in case of filter loading |
| Filter | Ultra-low Particulate Air (ULPA) / H14 filter with 99.999% efficiency at 0.3-0.1 μm |
| Airflow Velocity | Average inflow velocity of 0.45 m/s (90 fpm) |
| Air Quality | ISO 14644-1 Class 3 |
| C. Control Panel and Electrical | |
| Controller | Sentinel™ Gold Microprocessor Controller - Four-line LCD display - Soft touch keys for Blower, Light, and UV lamp with LED indicator |
| Modes | QuickStart Mode and Standby Mode |
| Timer | UV timer |
| Alarms | Audible and visual alarms |
| Electrical Requirements | Power rating: 220-240 V AC 50/60 Hz, 1 Ø |
| Power Consumption | 160 W |
| Heat Dissipation | 580 BTU/h |
| Lighting | Fluorescent lamp intensity: 1404 Lux |
| Optional UV Lamp | 253.7 nm |
| D. Ergonomics | |
| Servicing | Easy-to-service, all electrical components located at the back of the front panel |
| Control Panel | Centered and angled-down location of the control panel |
| Noise Emission | Low noise: 58.7 dBA (NSF/ANSI 49); 53.5 dBA (EN12469) |
| Optional Features | Ergonomic footrest and lab chair |
| Arm Rest | Angled arm rest for comfortable working position |
| Electrical Outlets | Easy-to-reach outlets located at the sides of the cabinet |
| Work Tray | Spill-containing single-piece work tray with large tray handles |
| E. Accessories | Support stand (Leveling feet or Caster wheels or Telescoping), Electrical Outlets, UV lamp, Service fixtures (Gas, water, etc.), IV Bars, Exhaust accessories (Air-tight damper, thimble exhaust collar, anti-blowback valve, tri-safe exhaust collar with alarm), Air-tight cable port, Footrest, Lab Chair, PVC arm rest, Pre-filter |
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing