- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Sample preparation Microwave digestion
- UltraWAVE ECR upgrade - Microwave Digestion System
HOME / APPLICATIONS & TECHNIQUES /
UltraWAVE ECR upgrade - Microwave Digestion System
Reference: MIL-MCLA1001
https://www.analis.com/shop/mil-mcla1001-ultrawave-ecr-upgrade-microwave-digestion-system-23937 https://www.analis.com/web/image/product.template/23937/image_1920?unique=9c80963SRC Technology
The ultraWAVE ECR is based on the SRC (Single Reaction Chamber technology), invented by Milestone several years ago (Patents pending).
SRC technology achieves extraordinary performance capabilities combining microwave heating with a high-pressure reactor which acts simultaneously as microwave cavity and vessel.
The ultraWAVE chamber is sealed, pressurized, heated, cooled, vented, and opened via a dedicated touch-screen control terminal.
Loading a rack of samples into the chamber is the only manual operation in an otherwise fully automated process of microwave-assisted sample preparation.
The outer surfaces of the vessel remain at room temperature throughout the entire microwave heating cycle.
As a result, the ultraWAVE is dramatically less labor intensive and easier to use compared to conventional microwave digestion systems.
- High performance. The highest temperatures & pressure capabilities and the fastest cooling time.
- Increased throughput. Double throughput of traditional microwave acid digestion instruments.
- No batching required. Simultaneous digestion of any sample type combination.
- Extra Corrosive Resistance. Use large amounts of HCl in open vessels without risk of corrosion!
- Ease of use. Cleaning of digestion vials is not necessary. No vessel assembly/disassembly.
- Expertise and Support. 30-years experience at your lab with the Milestone Connect.
- Compliance. USP 232/233 Chapters, ICH Q3D Guidelines and FDA regulation 21 CFR part 11.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing