- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Environmental monitoring Microbial air samplers
- TRIO.BAS MONO FILTER 100 Petri PACK with Cable
HOME / APPLICATIONS & TECHNIQUES /
TRIO.BAS MONO FILTER 100 Petri PACK with Cable
Reference: ORU-170K
https://www.analis.com/shop/oru-170k-trio-bas-mono-filter-100-petri-pack-with-cable-11963 https://www.analis.com/web/image/product.template/11963/image_1920?unique=b487480Single aspirating chamber for Petri plates with Hepa filter on air outlet.
The TRIO.BAS microbial air samplers have an electrical motor that do not produce particles after the cleaning procedure.
If the same air sampler is transferred in different environments with different levels of microbial contamination (from high to low – e.g. from C to A area), a risk of cross-contamination is possible.
In this case, to avoid this risk of transferring particles from the inside part of the aspirating chamber, it is suggested to adopt those air samplers that include an HEPA filter fixed on the air outlet of instrument.
The purpose of the filter is to stop the potential transfer of particles.
The HEPA filter is positioned externally and therefore its replacement is very simple.
- Main customers of TRIO.BAS MONO FILTER are pharmaceuticals, cleanrooms and biotech industries. The HEPA filter allows to capture the particulates
- The data is transferred via Bluetooth between the air sampler and a smartphone or tablet (Android version) and then to a PC or laptop
- The data may be transferred via cable, too. This is helpful for all companies that, due to internal policy, are not allowed to use wireless transfer
- It is possible to work either in manual or automatic mode
- Body IP 65 certified for protection from dust and water
- The battery is recharged by a power cable connected directly to the air sampler
- The use of sterile "Daily Shift" aspirating heads reduces the risk of contamination
Including with this reference:
- 1x TRIO.BAS MONO BLUETOOTH FILTER Air sampler (100 lts/min) Petri 90 plate with battery charger 100/240VCA 18VDC 859 mA with adapter for plug Eu/UK/USA - and CABLE for transfer data,
- 1 box HEPA filter and 1 calibration certificate
- 1x s/s ASPI HEAD Petri plate
- 1x COVER HEAD s/s to protect ASPI HEAD
- 1x ROBUSTUS STANDARD carrying case - 48x38x17h cm
Technical information
- Light weight, ergonomic and balanced design to facilitate handling with or without gloved hands
- Technopolymer shockproof body with antibacterial performances of surfaces
- Compliant with ISO 14698-1, EN 17141, GMP and GAMP
- Stainless steel aspirating head with quick bayonet closure, identification number and stainless steel cover to prevent contamination
- Volume of aspirated air: 100 l/m
- Selected volumes from 30 to 6.000 litres and 17 preset programs
- The aspirating chamber is suitable for 55 mm Contact plates or 90 mm Petri dishes
- HEPA filter
- Auto calibration: power/flow electronic real time control
- Power supply system: the instrument can be charged continuosly by AC powered source 110/240 Volt 50/60 Hz or by rechargeable batteries (inserted inside the air sampler)
- Cycles battery autonomy: 30.000 litres
- P65 certified protection from dust and water
- Language: English, French, German, Spanish, Italian
- Operative aspirating cycles: manual and automatic
- Memorized data: up to 1.000 samplings
- Configuration of 50 users and 50 places
- Delay time, fraction time and fraction number
- Bluetooth connection or cable for data transfer
- Automatic next calibration reminder
- Data integrity CFR 21 and GAMP5
- CE mark
- Dimension: 33x16x15h cm
- Weight: 1.440 gr
- Built in ISO 9001 premises
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing