- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Thermal analysis
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Material testing & characterization Packaging Heat and seal testing
- HSE-3 Laboratory Heat Sealer
HOME / APPLICATIONS & TECHNIQUES /
HSE-3 Laboratory Heat Sealer
Reference: RDM-HSE-3
https://www.analis.com/shop/rdm-hse-3-hse-3-laboratory-heat-sealer-146104 https://www.analis.com/web/image/product.template/146104/image_1920?unique=ad3a0d8The RDM HSE-3 is a precision laboratory heat sealer that produces high-quality, reproducible seals and determines the sealing parameters of flexible packaging materials. Digital control of temperature, pressure and seal time delivers accurate, consistent results for quality control and R&D in food packaging, pharmaceuticals and medical technology.
Its vertical design saves space and simplifies package positioning, reducing operator strain, while adjustable loading positions handle a wide range of pouch sizes and sealing angles. The HSE-3 delivers consistent, safe seals suited to demanding applications such as sterile medical device packaging, with full ISO 11607 compliance and support for seal-validation to the applicable standards.
What is the HSE-3 used for?
The unit seals flexible materials, porous and non-porous films, metal foils and blister packs, and simulates production conditions for blister packs and small pots. It is built for:
- Testing the heat sealability of flexible packaging materials
- Development and quality control in food, pharmaceutical and medical industries
- Sterile medical device packaging and seal validation
Technical specifications
- PID temperature control from room temperature to 300 °C, with ±0.5% accuracy and ±2 °C operational accuracy
- Digital pressure control from 0 to 100 psi (6.8 bar) via a precision regulator and digital display; accuracy ±5%, repeatability ±0.02 psi
- Aluminum seal jaws with precision-ground surfaces; lower jaw fitted with silicone rubber
- Single or dual heated jaws (top only, or top and bottom), in line with ASTM F2029
- Optional sealing surfaces including Matched Crimp and Teflon coating
- Quick-change system with dovetail guide and quick-coupling mechanism for easy jaw replacement
- Automatic cycle function for convenient testing of multiple samples
- Split design for easy mechanical rotation and space-saving storage
- Low maintenance: calibration needed only once every 12 months
How does it ensure validatable seals?
Accurate, repeatable seals come from PID temperature control, precision-ground aluminum jaws and digital pressure regulation, so temperature, pressure and seal time are held consistent across every cycle. Combined with ISO 11607 compliance and ASTM F2029 single/dual-jaw configurations, the HSE-3 supports the seal-validation that sterile medical and pharmaceutical packaging require.
Suitable for
- Flexible materials
- Porous and non-porous films
- Metal foils
- Blister packs and small pots
- Sterile medical device packaging
Request a demonstration or quote
Download the brochure below for full specifications. Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Technical information
Category | Specification |
Application | Packaging and material testing |
Standards | ASTM F2029 |
Industries | Medical, food and beverage, and packaging |
Temperature range | Room temperature to 300 °C |
Pressure range | 0 to 100 psi (6.8 bar) |
Seal width | 5 to 25 mm |
Seal time | Adjustable from 0.1 to 99.9 |
Seal length | Standard up to 300 mm |
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Thermal analysis
Toxicology
Urine analysis
Viscometers
Water purification
Weighing