- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometry
- Water purification
- Weighing
- Water purification
- Genie PURIST System set
HOME / APPLICATIONS & TECHNIQUES /
Genie PURIST System set
Reference: REP-RG0S00000K
https://www.analis.com/shop/rep-rg0s00000k-genie-purist-system-set-10568 https://www.analis.com/web/image/product.template/10568/image_1920?unique=689d05dGenie PURIST ultrapure water system produces Type I ultrapure water from RO, distilled or deionized water and it is designed for critical laboratory applications, offering desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure water in the lab. Quality of ultrapure water meet or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via wired or wireless.
- An optional automatic system shut-off upon detection of any water leakage.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- A universal water level sensor can be provided to prevent the system from pumping air.
Effective TOC level controlment
- Built-in 185/254 nm dual wavelength lamp reduces TOC level in ultrapure water.
- On-line TOC monitor based on complete oxidation methods (for TOC models).
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. Cartridge
Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
A full range of cartridges for various applications including ultra-low TOC, low Mg, low boron, ICP and DI type.
2. Control console
8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
The console screen and dispenser screens are water-frop proof. You can operate the console and dispenser with latex gloves on.
The system has two level password protection on display menu for safety purposes.
3. Dispenser
The volumetric function can automatically deliver the water volume you need once it is set up.
With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
4. Final Filter
Various final filters (optional) are applicable to ensure ultrapure water without particles, bacteria or pyrogen.
Technical information
| Feed Water Requirements | |
| Pure water | EDI water, RO water, Distilled water, Deionized water |
| Operating temperature | 5 - 35 ℃ |
| Feed water pressure | 0 - 1 bar (0 - 15 psi) |
| Product Water Quality | |
| Ultrapure water dispensing rate | Up to 2.0 L/min |
| Ultrapure water resistivity (@ 25℃) | 18.2 MΩ·cm |
| Ultrapure water TOC* | < 2 ppb |
| Particles in ultrapure water ( > 0.2 μm) | No particles (with a 0.2 μm final filter or RephiBio filter) |
| Microorganisms in ultrapure water | < 0.001 cfu/ml (with a 0.2 μm final filter or RephiBio filter) |
| Pyrogens (endotoxins) in ultrapure water | < 0.001 Eu/ml (with a RephiBio filter) |
| RNase in ultrapure water | < 0.5 pg/ml (with a RephiBio filter) |
| DNase in ultrapure water | <10 pg/ml (with a RephiBio filter) |
| Dimensions | |
| Main system dimensionsWidth × depth × height | 32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in) |
| Dispenser dimensionsWidth × depth × height | 21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in) |
| Weight | 17 kg |
| Input Voltage | 110 - 240 VAC |
| Operating Voltage | 24 VDC |
| Main system power | < 200 W |
*In the appropriate operating conditions, otherwise typically ≤5 ppb.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometry
Water purification
Weighing