Skip to Content
Microbiology POCT: RT-PCR Molecular Diagnostics

Analis has closed an exclusive partnership in microbiology with a new disruptive POCT RT-PCR Molecular Diagnostics supplier.

Point-of-care Testing (POCT) devices that deliver rapid diagnoses of infectious diseases became rapidly of first necessity and utility in any microbiology laboratory.
Notably in microbiology laboratory, the rapid turnaround time of POCT testing offers reduced management time between sample collection and diagnosis, optimizing clinical decision-making, regarding the hospitalization, triage process, isolation, and treatment of patients diagnosed with infectious diseases.
The partnership between Analis and FlashDx Inc - with an exclusive distribution on BENELUX market - is a first and significant step to fulfil new clinical diagnostics POCT challenges (Respiratory, GBS, STI, Gastro-Intestinal*, Arbovirus*, Meningitis*…) in and outside hospitals
Discover below the comprehensive panels  to detect various targets in a single test.

FlashDx Inc offers a turn-key Sample-to-Answer Molecular test platform based on proprietary sSPRT™ (semi-Solid Phase Real-Time PCR) technologies. FlashDx® has developed highly reliable but also cost-efficient multiplexed true Sample-to-Answer solutions. FlashDx systems can be easily connected to main LIS/Middleware (HL7). Product portfolio includes syndromic infectious test cartridges and scalable systems. The portfolio will expand to oncology and other disease areas.

* Ongoing CE Mark registration or under development/RUO.

Innovative semi-Solid Phase Real-Time PCR technologies empower high-quality multiplexed molecular tests.

FlashDx's proprietary semi-Solid Phase Real Time PCR (sSPRT™) technologies enables customers to achieve lab standard quality data for molecular testing in a near patient care setting.
Paired with our innovative microfluidic cartridge preloaded with buffer and lyophilized reagents, the system utilizes highly multiplexed TaqMan-like qPCR to detect various targets in a single test. This cost-effective solution with LIS-ready connection (HL7), meets all your needs for accuracy and affordability, making it the ideal choice for syndromic testing.
With ~1 minute hands-on time and no additional step of sample preparation, users can have the simplest workflow and true Sample-to-Answer solution for molecular detection.

Ask our experts

 
 


Easy 4-step sample-to-result process

Step 1: 30 sec
Load Sample

FlashDX Workflow Step 1 Load sample true Sample to Answer solution for molecular detection

Step 2: 20 sec
Load Cartridge

FlashDX Workflow Step 2 Load Cartridge true Sample to Answer solution for molecular detection

Step 3: 30 sec
Start Auto Processing

FlashDX Workflow Step 3 Start Auto Processing true Sample to Answer solution for molecular detection

Step 4: Report within 1h
Auto Report

FlashDX Workflow Step 4 Auto Report - true Sample to Answer solution for molecular detection

Fast & accurate multiplexed POC molecular tests to anyone, anywhere.

Fully automated Sample-to-Answer systems allow any user to complete multiplexed molecular tests with only 1 minute of hands-on time at any place. One test on a single sample provides answers against multiple targets. No more guesswork.

FlashDx sSPRT™ 4T/8T/12T Sample IVDR Label This Sample-to-Answer Molecular Test semi-Solid Phase Real-Time PCR

FlashDx sSPRT™ 4T/8T/12T Sample 

This single sample system (1-unit) is a Plug n'Play instrument with intuitive touchscreen, self-calibration, LIS-ready connection , etc. with many ports, of 4 to 12 samples, connected with one touch screen

Ask our experts

FlashDx-1000-E

FlashDx-1000-E   CE IVD Label

This single sample system (1-unit) is a Plug n'Play instrument with intuitive touchscreen, self-calibration, LIS-ready connection , etc. Complete a multi-target molecular test in a breeze.

Download FlashDX-1000E brochure             Ask our experts 

Key Features of FlashDx RT-PCR POCT Solutions

Easy to use POCT

 Easy to use

1 minute to load the sample and the cartridge.

Multiplexed up to 50 target POCT FlashDX

Multiplexed

One test, up to 50 targets tested.

Safe POCT minimize contamination

Safe

A fully enclosed cartridge minimises contamination risks.

Fast RT-PCR POCT Sample-to-answer system

Fast

Sample-to-answer system provides a report within one hour.

Flexible POCT throughput multi-system RT-PCR

Flexible

Flexible multi-system configuration satisfies different sample throughput needs.

Innovative microfluidic cartridge preloaded with buffer & lyophilized reagents

Paired with our innovative microfluidic cartridge preloaded with buffer and lyophilized reagents, the FlashDx systems utilize highly multiplexed TaqMan-like qPCR to detect various targets in a single test.

Respiratory Panel 1.1 POCT RT-PCT MOLECULAR DIAGNOSTICS TEST Cartridge

Respiratory Panel 1.1

CE IVD Label
The easy-to-use RP1.1 panel accurately testing 11 respiratory pathogens.      

Sample Types
Specimen: Nasopharyngeal, nasal or throat swabs
Transport Media: UTM/VTM* or saline (0.9%)    
Targets:
SARS-CoV-2 
Respiratory Syncytial Virus 
Human Metapneumovirus
Influenza A 
Influenza B 
Human Rhinovirus/
Enterovirus 
Parainfluenza Virus 1/2/3 
Adenovirus 
Bordetella pertussis 
Mycoplasma pneumoniae  

Watch the video 

SARS-CoV-2/Flu A/Flu B/RSV POCT RT-PCT MOLECULAR DIAGNOSTICS TEST Cartridge

SARS-CoV-2/Flu A/Flu B/RSV

CE IVD Label
Accurately differentiating all 4 viruses in one test helps everyone to get through the flu season more easily.

Sample Types
Specimen: Nasopharyngeal, nasal or throat swabs
Transport Media: UTM/VTM* or saline (0.9%)

Targets
SARS-CoV-2 - N, E, and ORF1ab genes
Flu A - Matrix gene
Flu B - NEP/NS2 gene
RSV A/B - L gene



FlashDX cartridge POCT test SARS-CoV-2 Cartridge

SARS-CoV-2 Cartridge

CE IVD Label
Rapid and robust detection of SARS-CoV-2 with 3 gene targets tested simultaneously: N, E and ORF1ab genes.

Sample Types
Specimen: Nasopharyngeal, nasal or throat swabs
Transport Media: UTM/VTM* or saline (0.9%)

Cartridge Group B Strep (GbS) Test

Group B Strep (GbS) 

 CE IVD Label
FlashDx's rapid GBS test delivers accurate results under an hour, enabling timely treatment for GBS-positive pregnant women thus preventing serious infections in newborns.

Sample Types
Specimen: Vaginal swabsTransport Media: UTM* or saline (0.9%)

Targets:
 
cfb/sip gene

FLASHDx POCT PANELS sSPRT™ STI Panel

sSPRT™ STI Panel  RUO label

Detecting six reproductive tract infection pathogens in a single test enables timely identification of mixed and asymptomatic cases, guiding effective clinical interventions.
Sample Types
Specimen: Vaginal or urethral swabs   /   Transport Media: UTM* or saline (0.9%)

Targets
Chlamydia trachomatis - Cryptic plasmid
Ureaplasma spp. - ure C gene
Mycoplasma hominis - 16S rRNA
Neisseria gonorrhoeae - Genomic target
Mycoplasma genitalium - mgpB gene
Trichomonas vaginalis - 18S rRNA

Our Product Categories in Microbiology POCT: RT-PCR Molecular Diagnostics