- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Centrifugation Ultracentrifuges
- SW 32 Ti Swinging-Bucket Rotor Assembly 32,000 rpm, 175,000 g, 6 x 38.5 mL
HOME / APPLICATIONS & TECHNIQUES /
SW 32 Ti Swinging-Bucket Rotor Assembly 32,000 rpm, 175,000 g, 6 x 38.5 mL
Reference: BEC-369650
https://www.analis.com/shop/bec-369650-sw-32-ti-swinging-bucket-rotor-assembly-32000-rpm-175000-g-6-x-38-5-ml-36943 https://www.analis.com/web/image/product.template/36943/image_1920?unique=9c80963This titanium top-loading swing-out
ultracentrifuge rotor is for use in Beckman Coulter instruments classified: H R S
The major applications covered are the separation of subcellular particles and viruses in density gradients.
This versatile rotor is also compatible with interchangeable SW 32.1 Ti bucket sets, which allow for a longer pathway and greater g-forces at the bottom of the thinner tubes. The SW 32 Ti and SW 32.1 Ti are swinging-bucket rotors designed to centrifuge up to six tubes each.
Technical information
Max RPM: 32,000
Max RCF: 175,000 x g
k Factor: 204
Tube Number / Volume: 6 x 38.5 mL
Size / Dimensions: 25 x 89 mm
Rotor Capacity: 231 mL
Related accessories, consumables & products
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing