- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Thermal analysis
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Color-Appearance and Physical tests Appearance
- Opacity Meter TOM-11
HOME / APPLICATIONS & TECHNIQUES /
Opacity Meter TOM-11
Reference: DAVI-TOM-11
https://www.analis.com/shop/davi-tom-11-opacity-meter-tom-11-147792 https://www.analis.com/web/image/product.template/147792/image_1920?unique=ad3a0d8The Davinor TOM-11 is a comparative opacity measuring instrument for plastic film, paper, laminates, printed packaging and other materials. Using a single light beam of approx. 4 mm, it measures relative light transmission on a scale of 0 to 100 opacity units, where 0 is perfectly transparent and 100 is fully opaque.
What does the TOM-11 measure?
The TOM-11 measures opacity (or relative light transmission, adjustable) with a resolution of **0.1%**. An LED light source measures the light attenuation (absorption) of the material under test, giving a clear, repeatable opacity value, which is essential for controlling the appearance and barrier-to-light properties of thin films, papers and printed packaging.
How does it work?
An LED light source passes a ~4 mm beam through the sample, and the instrument reads the attenuation as opacity or transmission. Automatic calibration runs at start-up and after any observed drift, keeping results stable and user-independent. The design lets operators use both hands to insert and position the sample without touching the instrument, and it works stand-alone (integrated LCD) or PC-connected via USB with the included Windows software for data capture and graphing.
Key advantages
- LED light source measuring the light attenuation (light absorption) of the material under test
- Results as relative transmission or opacity units (adjustable) with a resolution of 0.1%
- Designed for thin materials such as plastic films or paper
- Stand-alone or PC-connected via USB cable to a Windows PC, with integrated LCD screen for stand-alone use
- Windows software included for data capture and graphical display
- Automatic calibration at start-up and after observed drift
- Stable and insensitive to the environment, with user-independent results
- Easy to use: both hands free to insert and move the sample without touching the instrument
Suitable for
- Plastic film and foil
- Paper
- Laminates
- Printed packaging and other materials
Request a demonstration or quote
Download the brochure below for full specifications. Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Technical information
Category | Specification |
Measurement principle | Light attenuation (light absorption) measured with an LED light source |
Beam | Single light beam of approx. 4 mm |
Scale | 0 to 100 opacity units (0 = perfectly transparent, 100 = fully opaque) |
Output | Relative light transmission or opacity units (adjustable) |
Resolution | Up to 0.1% |
Operation | Stand-alone unit with integrated LCD screen, or connected to a Windows PC via USB cable |
Software | User-friendly Windows software for data capture and graphical display, included |
Calibration | Automatic at start-up and after observed drift |
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Thermal analysis
Toxicology
Urine analysis
Viscometers
Water purification
Weighing