- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Thermal analysis
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Thermal analysis Simultaneous Thermal Analysis (STA)
- High-Pressure STA HP 1/2
HOME / APPLICATIONS & TECHNIQUES /
High-Pressure STA HP 1/2
Reference: LINS-STA L84
https://www.analis.com/shop/lins-sta-l84-high-pressure-sta-hp-1-2-147782 https://www.analis.com/web/image/product.template/147782/image_1920?unique=ad3a0d8The LINSEIS High-Pressure STA (High-Pressure TG-DSC) determines simultaneous changes in mass (TG) and caloric reactions (HDSC) under a defined atmosphere and high pressure (up to 50/150 bar), across a temperature range of −170 °C to 1800 °C. Part of the Platinum series, it is built for demanding high-temperature and high-pressure applications.
What does the High-Pressure STA measure?
As a simultaneous thermal analyzer (STA), it records mass change (TG) and heat flow (DSC) at the same time, on the same sample, under identical pressure and atmosphere. Measuring both under pressure reveals reaction behavior, equilibria and thermal effects that are invisible at ambient pressure.
How does it work?
A single run captures TG and HDSC simultaneously under a defined atmosphere and high pressure (up to 150 bar) from −170 to 1800 °C, with high precision, high resolution and long-term drift stability. An optional pressure-controllable gas-mixing system (MFCs) sets precise atmospheres for reactive studies.
Key advantages
- Simultaneous TG and DSC under defined atmosphere and high pressure
- High precision and high resolution
- Long-term drift stability
- Developed for demanding conditions: the High-Pressure STA Platinum series meets the requirements of high-temperature and high-pressure applications
- Pressure-controllable gas mixing system (MFCs) as an option
Suitable for
- Pyrolysis studies
- Gasification of coal and biomass
- Testing of getter materials (O₂, H₂, etc.)
- Metal reduction/oxidation studies
Request a demonstration or quote
Ask Analis’ local Benelux experts for more information, a demonstration, or a personalized quote.
Technical information
Category | Specification |
Temperature range | RT to 1000 °C |
Max. pressure | 150 bar |
Vacuum | 10E-4 mbar |
Max. sample mass | 2/15/100 g |
Resolution | 0.1/0.5/10 µg |
DSC resolution | 0.3/0.4/1 µW |
DTA sensitivity | Undefined |
Options | Pressure-controllable gas mixing system (MFCs) |
Software
All LINSEIS thermal analysis instruments are PC-controlled. The individual software modules run exclusively under Microsoft® Windows® operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The 32-bit software contains all essential functions for preparing, running and evaluating an STA measurement. Together with its specialists and application experts, LINSEIS developed comprehensive, easy-to-understand and user-friendly application software.
General software features
- Text-editing program
- Data protection on power failure
- Thermocouple break protection
- Repeat measurements with minimal parameter input
- Evaluation of ongoing measurement
- Curve comparison of up to 32 curves
- Storage and export of evaluations
- ASCII data export and import
- Data export to MS Excel
- Analysis with multiple methods (DSC, TG, TMA, DIL, etc.)
- Zoom function
- 1st and 2nd derivative
- Programmable gas control
- Statistical evaluation package
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Thermal analysis
Toxicology
Urine analysis
Viscometers
Water purification
Weighing