- Analytical chemistry
- Automated Liquid Handling
- Capillary Electrophoresis
- Cell culture and Fermentation
- Cell health
- Centrifugation
- Chromatography (flash & prep)
- Cleaning
- Clinical Automation (TLA)
- Clinical IT solutions
- Clinical chemistry
- Clinical quality controls
- Color-Appearance and Physical tests
- DNA / RNA (Nucleic acids)
- Disinfection
- Electrochemistry
- Environmental monitoring
- Flow cytometry
- Flow cytometry Cell sorting
- Freeze drying
- Heating & cooling
- Hematology
- Imaging
- Immuno-Hematology
- Immunoassay
- In Vitro Fertilization (IVF)
- Lab furniture & design studies
- Liquid Handling (Manual)
- Mass spectrometers
- Material testing & characterization
- Metrology
- Microbiology (Clinical)
- Microscopy
- Moisture analysis
- Nephelometry
- POCT
- Particle characterization
- Platelet aggregation
- Protection cabinets
- Pumping
- Rheometers
- Sample preparation
- Shakers and stirrers
- Sterilization
- Storage
- Synthesis
- Tablet testing
- Texture analyzers
- Toxicology
- Urine analysis
- Viscometers
- Water purification
- Weighing
- Heating & cooling Incubation CO2 incubators
- IC050 56l CO2 incubator with standard sterilisation program
HOME / APPLICATIONS & TECHNIQUES /
IC050 56l CO2 incubator with standard sterilisation program
Reference: MEM-ICO50
https://www.analis.com/shop/mem-ico50-ic050-56l-co2-incubator-with-standard-sterilisation-program-4061 https://www.analis.com/web/image/product.template/4061/image_1920?unique=4e630bcThe smallest ICO, without compromise on safety
Where bench space is limited but reliability cannot be, the Memmert ICO50 brings the full safety architecture of the ICO range — dual-sensor temperature monitoring, dual-beam NDIR CO₂ control, and AutoSAFETY protection — into a compact 56 L footprint. It is the entry model of a four-size range (56 to 241 L), designed for labs running smaller batches of cell, bacteria or tissue cultures without sacrificing the redundant monitoring found on larger ICO models.
Key technical highlights:
- Dual-beam NDIR CO₂ control: digital electronic regulation with auto-diagnostic system, acoustic fault indication, and barometric pressure compensation
- Twin Pt100 temperature sensors (DIN Class A, 4-wire): mutual monitoring, automatic error takeover, accuracy ±0.1 K at 37°C
- AutoSAFETY (ASF): independent over-/undertemperature protection following setpoint at preset tolerance; automatic heating/cooling cutoff; visual and acoustic alarm
- Built-in sterilization program: 60 minutes at 180°C, without removing the sensors
- ControlCOCKPIT TwinDISPLAY: adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT color displays, 9 languages (DE, EN, ES, FR, PL, CZ, HU, IT, ZH)
- SetpointWAIT function: process/program time only starts once the set temperature is reached
- 6-side full-surface heating concept: prevents condensation even in the smallest chamber of the range
- Ethernet LAN / USB connectivity: AtmoCONTROL software for programming, management and data transfer; program retained in memory in case of power failure
- Mobile alarm notifications: visual and acoustic alarm plus remote alert if temperature, CO₂, O₂ or humidity ranges are exceeded
- 3 years worldwide guarantee
Technical information
| Specification | Detail |
| Interior volume | 56 L |
| Interior dimensions (W x H x D) | 400 x 425 x 330 mm (D less 35mm for fan) |
| Interior material | Stainless steel 1.4301 (ASTM 304), corrosion resistant |
| Exterior dimensions (W x H x D) | 559 x 795 x 521 mm (D +56mm door handle) |
| Working temperature range | 5°C above ambient to +50°C |
| Setting temperature range | +18°C to +50°C |
| Setting accuracy (temperature) | 0.1°C |
| Temperature variation in chamber at 37°C | ±0.3 K |
| Temperature fluctuation over time at 37°C | ±0.1 K |
| Temperature sensors | 2x Pt100, DIN Class A, 4-wire circuit |
| CO₂ adjustment range | 0–20% |
| CO₂ setting accuracy | 0.1% |
| CO₂ variation over time | ±0.2% |
| CO₂ control technology | Dual-beam NDIR, digital electronic |
| O₂ adjustment range | 1–20% |
| O₂ setting accuracy | 0.1% |
| Humidity (standard, Peltier-limited) | 93% rh ±2.5% (with water dish full and inserted) |
| Humidity setting accuracy | 0.5% rh |
| Humidity active control (option K7) | 40–97% rh and rh-Off |
| Sterilization program | 60 min at 180°C (sensors remain in place) |
| Max. shelves | 5 (1 perforated stainless steel shelf standard) |
| Max. load (chamber / per shelf) | 75 kg / 15 kg |
| Interface | Ethernet LAN, USB |
| Voltage / load | 230V or 115V, 50/60Hz, approx. 1100 W |
| Ambient operating temperature | 10°C to 35°C |
| Ambient humidity | max. 70% rh, non-condensing |
| Max. installation altitude | 2,000 m above sea level |
| Overvoltage category | II |
| Pollution degree | 2 |
| Net / gross weight (with packaging) | 55 kg / 74 kg approx. |
| Packaging dimensions | 730 x 950 x 640 mm |
| Country of origin | Federal Republic of Germany |
| Customs tariff number | 8419 8998 |
| WEEE-Reg.-No. | DE 66812464 |
| Safety approval | Standard units are safety-approved and bear the test marks |
Standard equipment: works calibration certificate (chamber center, +37°C, 5% CO2); fully insulated stainless steel door with 2-point compression lock; inner glass door with 8mm Ø gas sampling port; CO2 connection set (hose, coupling, clamp); membrane filter for incoming gas; 1 perforated stainless steel shelf; 1 stainless steel water dish.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing