What is a hot air sterilizer?
In dry sterilization, hot air - with no water vapor or moisture - ensures that laboratory equipment and devices are sterile without having to use risky decontamination methods.
Each Memmert hot air sterilizer S is classified as a class IIb medical device. Memmert is bringing medical devices of class IIb into circulation in compliance with MDD 93/42/EEC until 26 May 2024 according to the transitional provisions by the (EU) 2017/745 article 120 (2).
From a technology point of view, a hot air sterilizer is the same as a laboratory oven, but it has medical device Class IIb certification.
Our products
Hot air steriliser SF30, forced air circulation, with SingleDISPLAY, 32 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 704 x 434 mm; stainless steel interior: 400 x 320 x 250 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1600 W
Hot air steriliser SN30, natural convection, with SingleDISPLAY, 32 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 704 x 434 mm; stainless steel interior: 400 x 320 x 250 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1600 W
Hot air steriliser SF55, forced air circulation, with SingleDISPLAY, 53 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 784 x 514 mm; stainless steel interior: 400 x 400 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2000 W
Hot air steriliser SN55, natural convection, with SingleDISPLAY, 53 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 784 x 514 mm; stainless steel interior: 400 x 400 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2000 W
Hot air steriliser SF75, forced air circulation, with SingleDISPLAY, 74 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 944 x 514 mm; stainless steel interior: 400 x 560 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2500 W
Hot air steriliser SN75, natural convection, with SingleDISPLAY, 74 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 944 x 514 mm; stainless steel interior: 400 x 560 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2500 W
Hot air steriliser SF110, forced air circulation, with SingleDISPLAY, 108 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 745 x 864 x 584 mm; stainless steel interior: 560 x 480 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2800 W
Hot air steriliser SN110, natural convection, with SingleDISPLAY, 108 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 745 x 864 x 584 mm; stainless steel interior: 560 x 480 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2800 W
Hot air steriliser SF160, forced air circulation, with SingleDISPLAY, 161 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 745 x 1104 x 584 mm; stainless steel interior: 560 x 720 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 3200 W
Hot air steriliser SN160, natural convection, with SingleDISPLAY, 161 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 745 x 1104 x 584 mm; stainless steel interior: 560 x 720 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 3200 W
Hot air steriliser SF260, forced air circulation, with SingleDISPLAY, 256 l, working-temperature range at least 10 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 824 x 1183 x 684 mm; stainless steel interior: 640 x 800 x 500 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 3400 W
Hot air steriliser SN260, natural convection, with SingleDISPLAY, 256 l, working-temperature range at least 5 °C above ambient temperature to +250 °C, setting temperature range +20 °C to +250 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 824 x 1183 x 684 mm; stainless steel interior: 640 x 800 x 500 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 3400 W