• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Laboratory freeze-dryer
Compact benchtop unit for efficient drying of larger sample quantities
Beta 1-8 LSCbasic basic device consists of a Compact tabletop unit for the effective drying of relatively large specimen quantities. The LDplus user interface makes the work very easy. You can choose from a wide range of configurations to adapt the freeze dryer optimally to your specific needs. Condenser temperature of –55 °C for drying aqueous products.
Special Features
- Conversion of product temperature and vacuum according to the vapour pressure curve above ice
- Touch screen
Equipped with natural refrigerants*
As a leading manufacturer of freeze drying systems, we use natural refrigerants to provide sustainable and environmentally friendly freeze drying solutions. Our innovations help reduce environmental impact and build a greener future.
In 2009, we became one of the first manufacturers to convert our laboratory and pilot freeze dryers to nonflammable refrigerants. As a result, our freeze dryers have a particularly low Global Warming Potential (GWP) index.
* 50 Hz version, technichal changes reserved
RVC 2-33 CDplus Infrared Vacuum Concentrator: Advanced Sample Preparation Technology
The RVC 2-33 CDplus Infrared Vacuum Concentrator from Martin Christ combines cutting-edge technology with user-friendly features, making it the ideal solution for laboratories in the Benelux and beyond. Whether you’re working with DNA/RNA, proteins, or sensitive chemical samples, this concentrator delivers precise, efficient, and reproducible results for your sample preparation needs.
Key Features of the RVC 2-33 CDplus
Efficient Infrared Heating
Accelerate sample evaporation while maintaining precise control. The infrared heating system ensures even heat distribution, preventing overheating and preserving sample integrity.Optimal Vacuum Control
The advanced vacuum system minimizes solvent bumping and enhances drying speed, especially for aqueous and organic solvents. Ideal for high-throughput laboratories.Compact, Space-Saving Design
With its small footprint, the RVC 2-33 CDplus is perfect for labs where bench space is at a premium. Despite its compact size, it handles large sample volumes efficiently.Customizable Rotors and Accessories
Tailor the system to your lab's needs with a range of rotors and adapters for microtubes, microplates, and other sample types.User-Friendly Interface
The intuitive control panel allows for easy programming and monitoring of your processes. Set parameters such as temperature, vacuum level, and run time with confidence.
Applications
The RVC 2-33 CDplus excels in a variety of applications, including:
- Genomic and proteomic research
- Sample concentration for analytical techniques (e.g., HPLC, GC-MS)
- Drying of samples with high water or organic solvent content
Why Choose the RVC 2-33 CDplus for Your Laboratory?
Martin Christ is a leader in freeze-drying and vacuum concentration solutions, offering unparalleled quality and reliability. By investing in the RVC 2-33 CDplus, you’re choosing a system that:
- Improves laboratory workflow efficiency
- Reduces downtime and maintenance
- Ensures consistent, high-quality results
Available in Belgium
Through Analis, official distributors of Martin Christ in Belgium, you can access expert support, quick delivery, and technical guidance for the RVC 2-33 CDplus and other laboratory equipment.
Order Your RVC 2-33 CDplus Today
Upgrade your lab's efficiency and precision with the RVC 2-33 CDplus Infrared Vacuum Concentrator. Contact Analis for a quote or to learn more about how this advanced concentrator can meet your specific needs.
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Rotational-Vacuum-Concentrator RVC 2-33 CDplus in IR version, 230 V, 50/60 Hz, efficient energy supply with halogen IR lamps, with measurement of the product temperature, bench top unit, stainless steel rotor chamber, magnetic drive system, solvent resistant inner glass lid, lid with electrical locking- and safety device, user-friendly control system CDplus (Concentrator Display plus) with LC-display, preselection of vacuum, heating temperature and time up to 30 programms, digital vacuum display of set and actual value, measuring range 1000 to 0.1 mbar (incl. ceramic sensor for high- and low-boiling solvents),
special voltage see part no. 120100
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Laboratory freeze-dryer
For efficient lyophilization of samples with the innovative Wireless Shelf Technology.
The Alpha 1-4 LSCplus Basic device consist in a compact tabletop unit for effective lyophilisation of specimens with innovative Wireless Shelf Technology. The freeze dryer can be configured with tried and tested accessories to meet your specific needs. The simple and intuitive LSCplus controller supports manual and automatic process control for reproducible results.
Two different drying methods are available to handle virtually every task. –55 °C condenser temperature for drying aqueous specimens.
Special Features
- Vacuum control
- Pressure rise test
- Defrost function
- Product temperature
- Program selector
Equipped with natural refrigerants*
As a leading manufacturer of freeze drying systems, Martin Christ uses natural refrigerants to provide sustainable and environmentally friendly freeze drying solutions. These innovations help reduce environmental impact and build a greener future.
In 2009, Martin Christ became one of the first manufacturers to convert laboratory and pilot freeze dryers to nonflammable refrigerants. As a result, their freeze dryers have a particularly low Global Warming Potential (GWP) index.
* 50 Hz version, technichal changes reserved
The Systec V-Series of top-loading vertical autoclaves in 8 different sizes with 40 to 150 liters chamber volume is distinguished by its small footprint and high chamber capacity. Result: optimal loading capacity with most standard media bottles and Erlenmeyer flasks.
Systec VX-150 Vertical, top-loading autoclave,
Chamber volume (liter) total /nominal: 166/150,
Chamber dimensions (mm) Ø x depth: 500 x 750.
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Vacuum oven VO49, with TwinDISPLAY, 49 l, working-temperature range at least 5 °C above ambient temperature to +200 °C, setting temperature range 20 °C - 200 °C; digital electronic pressure control from 5 - 1100 mbar, with pump control, optimised rinsing procedures for the pump membranes as well as signal output for pump ON/OFF, with thermoshelf with 2 connectors for thermoshelves in the back, safety glass door with inner bullet-proof glass and external anti-spinter screen; stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, uploading programmes and for online logging, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C and 20 mbar pressure; textured stainless steel exterior: 550 x 687 x 480 mm; stainless steel interior: 385 x 385 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1020 W
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Basic laboratory freeze-dryer.
Floor-mounted unit in compact design for demanding applications
Compact, mobile unit for effective lyophilisation of specimens with innovative Wireless Shelf technology. The freeze dryer can be configured with tried and tested accessories and shelves to meet your specific needs. The simple and intuitive LSCplus controller supports manual and automatic process control for reproducible results.
Two different drying methods are available to handle virtually every task. –85 °C for specimens with low eutectic points.
Special Features
- Vacuum control
- Pressure rise test
- Defrost function
- Product temperature
- Program selector
Equipped with natural refrigerants*
As a leading manufacturer of freeze drying systems, we use natural refrigerants to provide sustainable and environmentally friendly freeze drying solutions. Our innovations help reduce environmental impact and build a greener future.
In 2009, we became one of the first manufacturers to convert our laboratory and pilot freeze dryers to nonflammable refrigerants. As a result, our freeze dryers have a particularly low Global Warming Potential (GWP) index.
* 50 Hz version, technichal changes reserved
• Fully automatic, microprocessor control including 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid Media
12 Cleaning
• Integrated separate steam generator (no heating elements in sterilization chamber)
• Novel safety ring-lock closure system with lip seal
• Temperature and steam pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
• Flexible PT-100 temperature sensor for reference vessel
• Medium temperature-controlled sterilization time
• Electronic pressure transducer for pressure and temperature control
• "Autofill" - Automatic demineralized water feed for steam generation
• Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
• Start by clock / timer for programmed start time
• Steam exhaust condensation, water cooled, thermostatic controlled
• Common collector connection for all outlets
• Emptying valve
• Base plate for vessels, baskets etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent rapid cooling installation
• Prepared for subsequent installation of vacuum system
• Prepared for subsequent drying installation
• Safety cut of at low water level
• Safety cut of at excess temperature
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing