G15 15µm Silica Carbide Control for use with the LS 13 320 XR particle size analyzer.
G35D 35 µm Silica Carbide Control for use with the LS 13 320 XR particle size analyzer.
Cooling liquid refill for use on temperature controlled instruments, for all Sciex CE systems including the BioPhase, PA 800 Plus, CESI 8000 Plus and P/ACE MDQ instruments (Qty: 1).
Dye-labeled dideoxy terminator cycle sequencing kit for 96 reactions. Includes: a single tube Quick Start Master Mix containing thermostable DNA polymerase and pyrophosphotase, CEQ WellRED dye-labeled terminators (ddUTP, ddGTP, ddCTP, ddATP), dNTPs in sequencing reaction buffer; Sample Loading Solution (SLS); pUC18 control template; -47 sequencing primer; mineral oil and glycogen.
Set of 50x one hole disposable chambers for use in Shandon & RESOSPIN® configurations of Sigma 2-7 Cytocentrifuges
Echo® Qualified 384-Well COC Microplate, Low Dead Volume, Clear, Flat Bottom, Non-sterile, 50 plates/case
Echo® Qualified 384-Well Low Dead Volume (LDV) Source Microplates are designed to minimize dead volume when using the Echo® Liquid Handler.
This microplate is constructed of Cyclic Olefin Copolymer (COC) for optimal acoustic transfer performance and DMSO storage. Each lot of microplates is tested and certified to meet stringent performance specifications.
Additional benefits of the microplate include:
- compatibility with heat sealing devices,
- designed for barcode customization
- and optimized for robotic handling.
- Precise Manufacturing for Superior Results.
For best results, Echo Liquid Handlers are designed to use Echo Qualified 384-well and 1536-well Source Microplates for precise and accurate liquid transfer. Echo Qualified Microplates deliver the best possible results in compound storage and miniaturized assays, and each plate is insured to meet the specifications required for consistent acoustic transfers. Labcyte performs functional qualification tests on each microplate lot with an Echo Liquid Handler to verify that our microplates deliver superior precision and accuracy, and DMSO hydration measurements.
Echo® Qualified 384-Well Polypropylene 2.0 Plus Microplate, Clear, Flat Bottom, Surface Treated, 100 plates/case.
Echo® Qualified 384-Well Polypropylene (PP) Source Microplates ensure accurate and precise transfer with the Echo® Liquid Handler. This microplate is highly resistant to solvents including DMSO and buffers making it ideal for compound and sample storage.
Echo® Qualified 384-Well Polypropylene Microplate, Clear, Non-sterile
Echo® Qualified 384-Well Polypropylene (PP) Source Microplates ensure accurate and precise transfer with the Echo Liquid Handler. This microplate is highly resistant to solvents, including DMSO and buffers, making it ideal for compound and sample storage.
The Vi-CELL Focus Control is used during the autofocusing procedure when the system requires re-focusing. The focus control beads help the system refocus and offer a new recommended focus position. The cup of focus control is run similar to a sample run using the Vi-CELL carousel sample delivery method.
For use in the Vi-CELL BLU and Vi-CELL XR cell viability analyzers.
The Memmert ICO105 CO₂ Incubator is meticulously engineered to provide a stable and contamination-free environment, essential for the cultivation of cell cultures, bacterial cultures, and tissue cultures. With a chamber volume of 107 liters, this advanced CO₂ incubator features a standard sterilization program that also sterilizes the humidity and CO₂ sensors inside the chamber, ensuring uncompromised safety and sample integrity.
High-Precision CO₂ Incubator for Cell Culture Applications in Belgium, Netherlands, and Luxembourg
Specifically designed to meet the high demands of laboratories in the Benelux, the ICO105 offers industry-leading accuracy, intuitive operation, and certified sterilization—making it the ideal choice for research laboratories, clinical environments, and pharmaceutical development facilities across Belgium, the Netherlands, and Luxembourg.
Key Features:
- Precise Temperature Control: Operating within a range of 5 °C above ambient temperature up to +50 °C, the ICO105 ensures uniform temperature distribution with minimal fluctuation, safeguarding sensitive samples.
- Advanced CO₂ Regulation: Equipped with a digital electronic CO₂ control system utilizing a dual-beam NDIR sensor, it maintains CO₂ concentrations from 0 to 20% with high accuracy, ensuring optimal growth conditions.
- Active Humidity Control: With the optional active humidity control (option K7), the incubator offers a setting range of 40 to 97% relative humidity, minimizing evaporation and preventing contamination.
- Comprehensive Safety Features: The ICO105 includes an integrated over- and under-temperature protection system (AutoSAFETY), visual and acoustic alarms, and a battery-buffered ControlCOCKPIT to ensure continuous operation even during power failures.
- Efficient Sterilization: A standard sterilization program allows for sterilizing the interior, including all sensors, at 180 °C for 60 minutes without removal, ensuring a contamination-free environment.
- User-Friendly Interface: The TwinDISPLAY system provides intuitive control over all parameters, complemented by the AtmoCONTROL software for programming and data logging, facilitating compliance with FDA regulations.
Whether you're in academic research, hospital-based laboratories, or industrial quality control, the Memmert ICO105 delivers consistency, traceability, and trust. Contact our experts today for more information or to request a quote.
Kit Component of P/N 390953 and P/N A10663 (IgG Purity/Heterogeneity Kit.)
For use as an experimental control when separating reduced or non-reduced IgG, with a designated quantity of non-glycosylated heavy chain to test both the resolution and quantitation suitability of the assay prior to running unknowns.
Includes IgG Control Standard 1-pack and all chemistries.
The IgG Purity/Heterogeneity Assay has been developed for researchers employed in industrial biotechnology who are developing and manufacturing IgG reagents for research, diagnostic and therapeutic use.
This assay has been specified for use on the PA 800 Plus to assess the purity and heterogeneity of IgG reagents in both a reduced and non-reduced state. The methodology involves heat-denaturing a specified concentration of IgG (both reduced and non-reduced) in the presence of SDS, and separating these proteins by size using high-resolution capillary gel electrophoresis technology. This assay will detect impurities as low as 0.1% and includes an IgG control with a designated quantity of non-glycosylated heavy chain to test both the resolution and quantitation suitability of the assay prior to running unknowns
Assay chemistry includes:
• Separation Capillary, 57 cm x 50 µm ID bare fused-silica, (2)
• SDS Gel Separation Buffer (proprietary formulation), 140 mL
• SDS Sample Buffer, 100 mM Tris-HCl, pH 9.0/1% SDS, 50 mL
• IgG Control Standard, 1 mg/mL in SDS sample buffer , 1 mL
• Internal Standard, 10 kDa protein, 5 mg/mL, 0.4 mL
• Acidic Wash Solution, 0.1 N HCl, 100 mL
• Basic Wash Solution, 0.1 N NaOH, 100 mL
• IgG Purity and Heterogeneity Analysis Guide, (1)
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing