The VCX 130 is a laboratory-scale 130 watt model, programmable ultrasonic processor, and our most popular small volume system.
This model offers the same programmability as larger VCX versions.
The 1/4" probe (10 – 50 mL volumes) is included with the VCX 130, and a variety of accessories are available for various applications and sample volumes.
Part No. VCX 130A can be used to order the system without the standard probe.
Features:
- Programmable
- Pulse mode
- 10 hour timer
- Variable power output
- Wattage and Energy display
Incubator IN30, natural convection, with SingleDISPLAY, 32 l, working-temperature range at least 5 °C above ambient temperature to +80 °C, setting range +20 °C to +80 °C, with 1 grid, outside stainless steel door, inside glass door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +37 °C; textured stainless steel exterior: 585 x 704 x 434 mm; stainless steel interior: 400 x 320 x 250 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1600 W
Universal oven UF30, forced air circulation, with SingleDISPLAY, 32 l, working-temperature range at least 10 °C above ambient temperature to +300 °C, setting temperature range +20 °C to +300 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 704 x 434 mm; stainless steel interior: 400 x 320 x 250 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1600 W
VIVA® G4 Class II Type A2 Animal BSC, model VA2-4S8 G4 12'/1.2m
The new VA2 G4 with Centurion Touchscreen controller is NSF-certified and available in 12-inch opening model for mouse and rat cages, with standby height that easily activates standby mode.
VIVA® G4 (VA2 G4) is comprised of bright illumination using industry-leading dimmable LED combined with an ergonomically sloped front design. VIVA® G4 Universal Workstation is specifically devised for optimum work comfort making it a complete solution to your need for ergonomics, reinforced safety and operations efficiency in animal handling operations.
Key Features
- Centurion Touchscreen Controller
- Dimmable LED lighting system
- Ergonomic 12” sash opening for mouse and rat cages with Frameless, shatterproof, and UV-absorbing tempered glass
- Tray support beams and holder
- Standby height that activates standby mode sustaining ISO Class 3 work zone as the fan runs at half speed
- USB Port and Remote Modbus
- Cabinet Construction includes:
- Stainless steel side walls with side capture zones and negative pressure to optimize containment
- Single-piece work tray, spill retaining and easy to clean
- Green Product with energy-efficient DC ECM allows up to 70% energy savings
- Default cable port
- Optional 21 CFR Compliance
- ELISA-proven containment
- Pre-filter rack for capturing animal dander
- ULPA Filter
- Isocide™ Antimicrobial Powder Coating
- Vivarium mute to mute the sash unsafe alarm during large equipment loading
Incubator IN55, natural convection, with SingleDISPLAY, 53 l, working-temperature range at least 5 °C above ambient temperature to +80 °C, setting range +20 °C to +80 °C, with 1 grid, outside stainless steel door, inside glass door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +37 °C; textured stainless steel exterior: 585 x 784 x 514 mm; stainless steel interior: 400 x 400 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1000 W
The VC 505 is a cost effective alternative to the VCX model. This 500 watt system
offers the same processing power and choice of accessories as the VCX500 without
temperature monitoring or energy set point programming.
A standard ½” diameter probe with replaceable tip is included and many optional
accessories are available to meet the needs of any application.
Incubator IN75, natural convection, with SingleDISPLAY, 74 l, working-temperature range at least 5 °C above ambient temperature to +80 °C, setting range +20 °C to +80 °C, with 2 grids, outside stainless steel door, inside glass door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +37 °C; textured stainless steel exterior: 585 x 944 x 514 mm; stainless steel interior: 400 x 560 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1250 W
Universal oven UF55, forced air circulation, with SingleDISPLAY, 53 l, working-temperature range at least 10 °C above ambient temperature to +300 °C, setting temperature range +20 °C to +300 °C, with 1 grid, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 784 x 514 mm; stainless steel interior: 400 x 400 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2000 W
Universal oven UF75, forced air circulation, with SingleDISPLAY, 74 l, working-temperature range at least 10 °C above ambient temperature to +300 °C, setting temperature range +20 °C to +300 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 585 x 944 x 514 mm; stainless steel interior: 400 x 560 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2500 W
Incubator IN110, natural convection, with SingleDISPLAY, 108 l, working-temperature range at least 5 °C above ambient temperature to +80 °C, setting range +20 °C to +80 °C, with 2 grids, outside stainless steel door, inside glass door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +37 °C; textured stainless steel exterior: 745 x 864 x 584 mm; stainless steel interior: 560 x 480 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1400 W
Universal oven UF110, forced air circulation, with SingleDISPLAY, 108 l, working-temperature range at least 10 °C above ambient temperature to +300 °C, setting temperature range 20 °C to 300 °C, with 2 grids, stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, double overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C; textured stainless steel exterior: 745 x 864 x 584 mm; stainless steel interior: 560 x 480 x 400 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 2800 W
The VCX 500 offers 500 watts of power to handle a range of liquid processing applications. This model shares the same microprocessor based operating system and programming screens as the VCX750 system.
Using a variety of accessories, the system can process a wide range of sample types and volumes for many different applications.The VCX 500 includes a standard 1/2" diameter probe (50 – 250mL volumes) with replaceable tip.
Part No. VCX 500A can be used to order the system without the standard probe.
Automated Liquid Handling
Capillary Electrophoresis
Cell culture and Fermentation
Cell health
Centrifugation
Chromatography (flash & prep)
Cleaning
Clinical Automation (TLA)
Clinical IT solutions
Clinical chemistry
Clinical quality controls
Color-Appearance and Physical tests
DNA / RNA (Nucleic acids)
Disinfection
Electrochemistry
Environmental monitoring
Flow cytometry
Flow cytometry Cell sorting
Freeze drying
Heating & cooling
Hematology
Imaging
Immuno-Hematology
Immunoassay
In Vitro Fertilization (IVF)
Lab furniture & design studies
Liquid Handling (Manual)
Mass spectrometers
Material testing & characterization
Metrology
Microbiology (Clinical)
Microscopy
Moisture analysis
Nephelometry
POCT
Particle characterization
Platelet aggregation
Protection cabinets
Pumping
Rheometers
Sample preparation
Shakers and stirrers
Sterilization
Storage
Synthesis
Tablet testing
Texture analyzers
Toxicology
Urine analysis
Viscometers
Water purification
Weighing